{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"7SR4501-2GA10-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"7SR4501-2GA10-1AA0","canonicalUrl":"https://aoctrl.com/siemens/7SR4501-2GA10-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/7SR4501-2GA10-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"ARGUS Non-directional overcurrent-time protection Polycarbonate enclosure, 4x current transformer, 2 BI/2 BQ, pulse output, 9 LEDs Measuring input: 5 A, 50/60 Hz Auxiliary voltage: current transformer supplied USB front interface No protocol (no interface on the rear) Device front: standard version Protection function package: basic version","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["General Purpose Relays"],"specifications":{"HSR":"No","PRP":"No","DHCP":"No","RSTP":"No","SNTP":"No","DIGSI":"Yes","Control":"No","Maximum":"60 °C","Minimum":"-10 °C","Monitoring":"Yes","CFC standard":"No","IEC 61850-9-2":"No","CFC arithmetic":"No","IEC 60870-5-104":"No","lifecycle_stage":"current","PROFIBUS DP slave":"No","DIGSI to USB A port":"No","Switching Statistics":"No","Time Synchronization":"No","Design Of The Display":"2","Quick Logic (Reyrolle)":"No","Frame Size Of Enclosure":"4","Number Of Function Keys":"7","Plug-In Terminal Blocks":"Yes","Inrush Current Detection":"No","Number Of Parameter Sets":"1","Parameter Set Switchover":"No","number of LEDs / maximum":"9","Circuit Breaker Monitoring":"No","Sequence-Of-Events Recorder":"No","reclosing lockout (ANSI 66)":"No","automatic reclosing (ANSI 79)":"No","number of IO modules expandable":"Yes","teleprotection scheme (ANSI 85)":"No","graphical logic editor (Reyrolle)":"No","Number Of Current Inputs / Maximum":"4","Number Of Digital Inputs / Maximum":"2","Type Of Interface / Service Interface":"Yes","Expanded / Min./Max. Values, Mean Values":"No","Of Operational Measured Value / Standard":"Yes","protection function / I-trip (ANSI SOFT)":"Yes","Protection Function / Three-Pole Tripping":"Yes","IEC 61850, 100 Mbit/s, dual RJ45 connector":"No","IEC 61850, 100 Mbit/s, 1300 nm dual LC port":"No","PROFINET IO, 100 Mbit/s, dual RJ45 connector":"No","DNP 3 serial, RS 485 with terminal connection":"No","Switching Procedures For Application Controls":"No","protection function / fault locator (ANSI FL)":"No","Fault Recording For Analog And Digital Signals":"No","Modbus TCP/IP, 100 Mbit/s, dual RJ45 connector":"No","Protection Function / External Trip Initiation":"Yes","IEC 60870-5-103, 820 nm with ST(BFOC) connector":"No","protection function / arc protection (ANSI AFD)":"No","IEC 60870-5-103, RS 485 with terminal connection":"No","protection function / closing lock-out (ANSI 86)":"Yes","Modbus RTU slave, RS 485 with terminal connection":"No","Suitability For Use / Overcurrent-Time Protection":"Yes","protection function / frequency protection (ANSI 81)":"No","protection function / power swing blocking (ANSI 68)":"No","protection function / unbalance protection (ANSI 46)":"No","DNP 3 serial, RS 485 with D-sub connection technology":"No","protection function / overvoltage protection (ANSI 59)":"No","protection function / differential protection (ANSI 87)":"No","protection function / undercurrent protection (ANSI 37)":"No","protection function / undervoltage protection (ANSI 27)":"No","Modbus RTU slave, RS 485 with D-sub connection technology":"No","PROFIBUS DP slave, RS 485 with D-sub connection technology":"No","protection function / phase-rotation supervision (ANSI 47)":"No","protection function / trip-circuit supervision (ANSI 74TC)":"No","protection function / thermal overload protection (ANSI 49)":"No","protection function / directional power monitoring (ANSI 32)":"No","protection function / grounding protection (machine) (ANSI 64)":"No","protection function / frequency variation protection (ANSI 81R)":"No","protection function / dynamic response value changeover (ANSI 51C)":"No","protection function / circuit breaker failure protection (ANSI 50BF)":"No","protection function / directional ground fault protection (ANSI 67N)":"No","protection function / sensitive ground current protection (ANSI 50Ns)":"No","protection function / intermittent ground fault protection (ANSI 50Ns)":"No","protection function / overvoltage protection zero-sequence system (ANSI 59N)":"No","protection function / voltage-dependent overcurrent-time protection (ANSI 51V)":"No","protection function / directional overcurrent-time protection, phases (ANSI 67)":"No","protection function / overvoltage protection negative-sequence system (ANSI 47)":"No","protection function / high-impedance ground fault differential protection (ANSI 87N)":"No","protection function / overcurrent-time protection negative sequence system (ANSI 46)":"No","protection function / directional sensitive ground-fault detection for resonant-grounded systems and isolated systems (ANSI 67Ns)":"No"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/133c6f79a208791750c8cf8b60dcc10e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1029372&mlfb=7SR4501-2GA10-1AA0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/7SR4501-2GA10-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/7SR4501-2GA10-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}