{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A63-30-11-84","brand":"ABB","brandSlug":"abb","productSlug":"A63-30-11-84","canonicalUrl":"https://aoctrl.com/abb/A63-30-11-84","factsUrl":"https://aoctrl.com/api/mcp/products/A63-30-11-84","rawCanonicalId":null},"summary":{"shortDescription":"Eaton A-Line Series A63-30-11-84 IEC contactor, 3-pole, 65 A motor current, 90 A general-purpose, 600 V rated, 120 V AC coil, with 1 N.O. and 1 N.C. auxiliary contact block.","salesMarkdown":"## EOL Lifecycle — What It Means for Procurement For a line-down or BOM-fill situation, the A63-30-11-84 is sourced through independent distribution — quantities are confirmed at RFQ, and there is no guaranteed stock level. The buyer should treat this as a last-time-buy or surplus-channel procurement, not a routine replenishment. ## Rated Current and Coil Voltage — Fit Confirmation Rated 65 A motor current and 90 A general-purpose current at 600 V, per the IEC duty classification. The 65 A figure is the AC-3 motor-switching rating — the current the contactor can break under starting conditions. The 90 A figure applies to resistive or general-purpose loads (AC-1). Coil is 120 V AC. The control circuit must supply 120 V AC at the coil terminals; a 24 V DC or 240 V coil variant is a different order code. Verify the control transformer tap before committing the BOM line. Three-pole configuration with one normally-open and one normally-closed auxiliary contact block integrated. The aux contacts are rated for the same 600 V insulation class as the main poles. ## Panel Integration and Mounting Part of the Eaton A-Line Series, A63 frame. The contactor mounts on a DIN rail or panel via the frame's integral latch — no separate mounting bracket needed. The A63 frame size is the physical envelope that determines side-by-side spacing and busbar connection points. The 1 N.O. + 1 N.C. auxiliary block is factory-installed on the front of the contactor. It occupies the standard auxiliary slot, so adding a second block would require a different front-mount accessory.","metaTitle":"A63-30-11-84 Eaton Contactor, 65A, 3-Pole, 120V Coil, EOL","metaDescription":"Eaton A63-30-11-84 IEC contactor, 65A motor current, 3-pole, 120V AC coil. EOL lifecycle. Sourced to order against RFQ. 1 N.O. + 1 N.C. aux block.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Amps":"65","Type":"Contactor","Poles":"3","title":"A63-30-11-84","description":"3P, Contactor, IEC, 120V AC|65 Motor Current Amp, 90 General Purpose Amp, 600V Rated, 120V AC Coil. A-Line Series, A63 Frame, 3-Pole, IEC Contactor with 1 N.O. & 1 N.C. Auxiliary Contact Block.","lifecycle_stage":"eol_hot","Volts AC Control":"120"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$641.01","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce24883bdf9b77875f002da789a30c44.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the motor current rating of the A63-30-11-84?","answer":"The motor current rating is 65 A under IEC AC-3 duty. The general-purpose (AC-1) rating is 90 A. Both figures apply at 600 V rated insulation voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/A63-30-11-84","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/A63-30-11-84 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}