{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C15504","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C15504","canonicalUrl":"https://aoctrl.com/schneider/A9C15504","factsUrl":"https://aoctrl.com/api/mcp/products/A9C15504","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 TL40 impulse relay, 1P, 16 A, 230 V AC 50 Hz control, 1 NO, DIN rail, IP20.","salesMarkdown":"Rated 16 A at 250 V AC 50 Hz, it switches a single-pole normally-open (1 NO) contact. Control is via a 230 V AC 50 Hz impulse signal drawing 19 VA during the 50 ms pulse. The relay is rated for 200,000 cycles under AC-22 duty (resistive and mixed loads up to 16 A). Mounts on a DIN rail, occupies an 18 mm width (one modular pitch). The 87 mm height and 69 mm depth fit standard distribution boards. IP40 when installed in an enclosure. Tunnel-type terminals accept up to 4 mm² rigid or 2.5 mm² flexible cable — sized for standard lighting or small motor contactor control circuits. The 16 A rated current at 250 V AC is the continuous thermal current (Ith) for resistive loads — this relay can switch lighting banks, contactor coils, or solenoid valves within that limit. The AC-22 electrical durability of 200,000 cycles means it's rated for mixed resistive and inductive loads up to 16 A, not just resistive. The 5 switching operations per minute maximum is a thermal limit on the coil — don't pulse it faster than every 12 seconds in continuous use. The 2.5 kV impulse withstand voltage (Uimp) gives it adequate margin for 230/400 V distribution systems.","metaTitle":"Schneider Electric A9C15504 Acti9 TL40 Impulse Relay, 16 A,","metaDescription":"Schneider Electric A9C15504 Acti9 TL40 impulse relay, 16 A rated current, 1 NO contact, 230 V AC control, DIN rail mount, IP20, IEC 60669 compliant, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"69 mm","Poles":"1P","Width":"18 mm","Height":"87 mm","Standards":"IEC 60669-1 IEC 60669-2-2","Noise level":"60 dB","9 Mm Pitches":"2","Control type":"Remote and manual control","Network type":"AC","Product name":"Acti9 TL40","Mounting mode":"Fixed","Quality labels":"NF","lifecycle_stage":"current","Impulse duration":"50 ms","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Pollution degree":"3","Range Of Product":"Acti9","Device short name":"TL40","Network frequency":"50 Hz","Relative humidity":"95 % at 55 °C","Tightening torque":"1 N.m","Device application":"Standard","[In] rated current":"16 A","Control signal type":"Impulse","Remote control type":"Illuminated push-button 3 mA","Switching frequency":"5 switching operations/minute","Electrical durability":"AC-22: 200000 cycles","Wire stripping length":"9 mm","Connections - terminals":"Power circuit: tunnel type terminals 1 cable(s) 1...4 mm² rigid Power circuit: tunnel type terminals 2 cable(s) 1...2.5 mm² rigid Power circuit: tunnel type terminals 1 cable(s) 1...4 mm² flexible Power circuit: tunnel type terminals 2 cable(s) 1...2.5 mm² flexible Control circuit: tunnel type terminals 1 cable(s) 0.5...1.5 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 0.5...1.5 mm² flexible Power circuit: tunnel type terminals 1 cable(s) 1...4 mm² flexible with ferrule Power circuit: tunnel type terminals 2 cable(s) 1...2.5 mm² flexible with ferrule Control circuit: tunnel type terminals 1 cable(s) 0.5...1.5 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 (on opening) IP40 conforming to IEC 60529 (in enclosure)","Pole contact composition":"1 NO","Product or component type":"Impulse relay","[Uc] control circuit voltage":"230 V AC 50 Hz","[Ui] rated insulation voltage":"500 V AC","[Ue] rated operational voltage":"250 V AC 50 Hz","Hold-in power consumption in VA":"19 VA","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-20...50 °C","[Uimp] rated impulse withstand voltage":"2.5 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9C15504/impulse-relay-acti9-tl40-1p-1no-16-a-230-v-ac-50-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C15504/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the A9C15504?","answer":"16 A rated current (In) at 250 V AC 50 Hz, controlled by a 230 V AC 50 Hz impulse signal drawing 19 VA, with a single-pole normally-open contact rated for 200,000 cycles under AC-22 duty."},{"question":"What compliance standards does the A9C15504 meet?","answer":"It complies with IEC 60669-1 and IEC 60669-2-2 for switches for household and similar fixed electrical installations. It carries NF quality label certification. IP20 per IEC 60529 on the opening, IP40 when enclosed."},{"question":"How is the A9C15504 mounted and wired?","answer":"Snap-on DIN rail mount, 18 mm wide (1 modular pitch). Terminals accept 1 to 4 mm² rigid or 1 to 2.5 mm² flexible cable for the power circuit, and 0.5 to 1.5 mm² for the control circuit. Tightening torque is 1 N·m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C15504","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C15504 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}