{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C15507","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C15507","canonicalUrl":"https://aoctrl.com/schneider/A9C15507","factsUrl":"https://aoctrl.com/api/mcp/products/A9C15507","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 TL impulse relay, A9C15507, 2P, 16 A rated current, 230 V AC 50 Hz control, DIN rail mount.","salesMarkdown":"The Schneider Electric A9C15507 is an Acti9 TL impulse relay — a 2-pole, 16 A rated device controlled by a 230 V AC 50 Hz impulse signal, designed for remote and manual switching of lighting or resistive loads in commercial and industrial final distribution boards. Compliance with IEC 60669-2-2 and IEC 60669-1 confirms it meets the international standard for electronic switches in household and similar fixed electrical installations, making it a defensible choice for tender specifications that require third-party certification. The 16 A rated current (In) and 250 V AC operational voltage (Ue) define the maximum continuous load this relay can switch — sized for lighting circuits up to 4 kW on a 230 V line, or resistive heating loads within that envelope. Electrical durability is rated at 200,000 cycles under AC-22 duty (mixed resistive and inductive loads), which is the relevant endurance figure for lighting contactor applications — not the mechanical life, but the cycles it can deliver while switching rated current. The impulse control signal requires a 3 mA illuminated push-button or equivalent pulse source; the relay latches mechanically on each pulse, so the control wire need only carry a brief 50 ms pulse, not a continuous hold signal. Pollution degree 3 rating means the relay is designed for environments with conductive or dry non-conductive pollution — typical of control panels in industrial halls where some dust and humidity are present, but not direct washdown. For audit purposes, the manufacturer provides compliance documentation covering the IEC standards cited on the nameplate; the NF quality label further confirms conformity to French national standards, which may be required for public-sector tenders in that jurisdiction. Terminals are tunnel type: power circuit accepts 1 to 4 mm² rigid or flexible (single cable) or 2 × 1 to 2.5 mm² (two cables); control circuit accepts 0.5 to 1.5 mm². Strip length is 9 mm, tightening torque 1 N·m — standard for a 16 A class relay. Dimensions are 18 mm wide × 84 mm high × 60 mm deep, so it occupies one DIN-rail module and leaves clearance for wiring ducts or adjacent devices in a standard 60 mm deep enclosure. Operating temperature range is -20 to 50 °C, storage -40 to 80 °C, with 95% relative humidity at 55 °C — adequate for unconditioned electrical rooms but not for outdoor installation without a weatherproof enclosure.","metaTitle":"Schneider Electric A9C15507 Acti9 TL Impulse Relay, 16 A, 2P","metaDescription":"Schneider Electric A9C15507 Acti9 TL impulse relay, 16 A rated current, 2P, 230 V AC control, DIN rail mount, IEC 60669 compliant, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"60 mm","Poles":"2P","Width":"18 mm","Height":"84 mm","Standards":"IEC 60669-2-2 IEC 60669-1","Noise level":"60 dB","9 Mm Pitches":"2","Control type":"Remote and manual control","Network type":"AC","Product name":"Acti9 TL","Mounting mode":"Fixed","Quality labels":"NF","Tropicalisation":"2","lifecycle_stage":"current","Impulse duration":"50 ms","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Pollution degree":"3","Range Of Product":"Acti9","Device short name":"TL","Network frequency":"50 Hz","Relative humidity":"95 % at 55 °C","Tightening torque":"1 N.m","Device application":"Standard","[In] rated current":"16 A","Control signal type":"Impulse","Remote control type":"Illuminated push-button 3 mA","Switching frequency":"5 switching operations/minute","Electrical durability":"AC-22: 200000 cycles","Wire stripping length":"9 mm","Connections - terminals":"Power circuit: tunnel type terminals 1 cable(s) 1...4 mm² rigid Power circuit: tunnel type terminals 2 cable(s) 1...2.5 mm² rigid Power circuit: tunnel type terminals 1 cable(s) 1...4 mm² flexible Power circuit: tunnel type terminals 2 cable(s) 1...2.5 mm² flexible Control circuit: tunnel type terminals 1 cable(s) 0.5...1.5 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 0.5...1.5 mm² flexible Power circuit: tunnel type terminals 1 cable(s) 1...4 mm² flexible with ferrule Power circuit: tunnel type terminals 2 cable(s) 1...2.5 mm² flexible with ferrule Control circuit: tunnel type terminals 1 cable(s) 0.5...1.5 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 (on opening) IP40 conforming to IEC 60529 (in enclosure)","Pole contact composition":"2 NO","Product or component type":"Impulse relay","[Uc] control circuit voltage":"230 V AC 50 Hz","[Ui] rated insulation voltage":"500 V AC","[Ue] rated operational voltage":"250 V AC 50 Hz","Hold-in power consumption in VA":"19 VA","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-20...50 °C","[Uimp] rated impulse withstand voltage":"2.5 kV","Comb busbar and distribution block compatibility":"Upside: ProDis"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9C15507/impulse-relay-tl-2p-2-no-16a-coil-230-vac-50hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C15507/alternatives.json"},"ai":{"faq":[{"question":"What is the A9C15507's rated current and pole configuration?","answer":"It is a 2-pole impulse relay with a rated current (In) of 16 A, controlled by a 230 V AC 50 Hz impulse signal."},{"question":"What compliance standards does the A9C15507 meet?","answer":"It complies with IEC 60669-2-2 and IEC 60669-1 for electronic switches, and carries the NF quality label for French national standards."},{"question":"What is the electrical durability of the A9C15507?","answer":"It is rated for 200,000 cycles under AC-22 duty, which covers mixed resistive and inductive loads typical of lighting circuits."},{"question":"What are the mounting dimensions of the A9C15507?","answer":"It is 18 mm wide, 84 mm high, and 60 mm deep, designed for DIN-rail mounting in standard distribution panels."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C15507","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C15507 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}