{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C15908","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C15908","canonicalUrl":"https://aoctrl.com/schneider/A9C15908","factsUrl":"https://aoctrl.com/api/mcp/products/A9C15908","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 CDS, single-phase load-shedding contactor, 2 channels, 1P, 230 V AC, 15 A non-priority / adjustable 5-90 A priority circuit, IP20, DIN rail.","salesMarkdown":"The Schneider Electric A9C15908 is an Acti9 CDS single-phase load-shedding contactor with two channels — one non-priority circuit rated at 15 A and one priority circuit adjustable from 5 to 90 A. The priority circuit's adjustable range (5 to 90 A) lets you set the trip threshold via the 12-position rotary dial (settings: 75, 45, 20, 90, 5, 10, 30, 60, 50, 40, 15, 25 A), so you match it to the critical load's actual draw. The 12 VA power consumption is the coil's steady-state draw — negligible for the panel's control transformer budget. The operating temperature range (-5 to 55 °C) covers most control-panel environments, and the 95 % RH at 55 °C rating confirms it handles high-humidity plant floors without condensation issues. The 90 mm width and 77 mm height fit a standard 4-module DIN-rail footprint (10 x 9 mm pitches). The screw terminals accept up to 10 mm² flexible on the non-priority side and up to 50 mm² rigid on the priority side — sized for the higher current path. Compliant with EN 50081-1, EN 50081-2, and NF C 61-750. Depth is 60 mm, which clears most standard enclosures.","metaTitle":"Schneider Electric A9C15908 Acti9 CDS Load-Shedding Contacto","metaDescription":"Schneider Electric A9C15908 Acti9 CDS single-phase load-shedding contactor. 2 channels, 230 V AC, 15 A non-priority / 5-90 A priority circuit. Active production. IP20. DIN rail mou","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"60 mm","Width":"90 mm","title":"A9C15908","Colour":"White (RAL 9003)","Height":"77 mm","Setting":"75 45 20 90 5 10 30 60 50 40 15 25","Standards":"EN 50081-1 NF C 61-750 EN 50081-2","description":"CDS - single phase load-shedding contactor - 2 channels","9 Mm Pitches":"10","Product name":"Acti9 CDS","Rated current":"15 A for non-priority circuit Adjustable from 5 to 90 A for priority circuit","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Local signalling":"Load-shedding indication: 2 LEDs (yellow)","Mounting support":"35 mm symmetrical DIN rail Wall mounted Panel mounting","Range Of Product":"Acti9","Device short name":"CDS","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"Non-priority circuit: 2 N.m Priority circuit: 3.5 N.m","Number of channels":"2","Wire stripping length":"12 mm 13 mm","Connections - terminals":"Non-priority circuit: screw terminal2.5...10 mm² flexible Non-priority circuit: screw terminal2.5...10 mm² rigid Priority circuit: screw terminal10...35 mm² flexible Priority circuit: screw terminal10...50 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529","Power consumption in VA":"12 VA","Product or component type":"Load-shedding contactor","Control and monitoring type":"Cascade","[Ue] rated operational voltage":"230 V AC - 15...10 % at 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-5...55 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ng/en/product/A9C15908/cds-single-phase-loadshedding-contactor-2-channels/"},"ai":{"faq":[{"question":"What are the key ratings for the A9C15908?","answer":"It is a 2-channel single-phase load-shedding contactor rated 230 V AC, 15 A on the non-priority circuit, and adjustable 5 to 90 A on the priority circuit. Power consumption is 12 VA. IP20 rated."},{"question":"What are the mounting dimensions?","answer":"Width 90 mm, height 77 mm, depth 60 mm. Mounts on 35 mm DIN rail, panel, or wall. Occupies 10 x 9 mm pitches on the rail."},{"question":"What compliance standards does it meet?","answer":"Compliant with EN 50081-1, EN 50081-2, and NF C 61-750. Tropicalisation class 2 per IEC 60068-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C15908","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C15908 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}