{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C52416","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C52416","canonicalUrl":"https://aoctrl.com/schneider/A9C52416","factsUrl":"https://aoctrl.com/api/mcp/products/A9C52416","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N integrated control circuit breaker, A9C52416, 16 A rated, 4 poles, curve C, 20 kA breaking capacity at 240 V AC.","salesMarkdown":"The Schneider Electric A9C52416 is a Reflex iC60N integrated control circuit breaker from the Acti9 range, combining overcurrent protection with remote switching capability in a single 4-pole unit rated at 16 A with a C trip curve. Breaking capacity is 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC, certified to EN/IEC 60947-2 — sufficient for most commercial and light industrial distribution panels where fault levels stay under those thresholds. ## Control and signalling Control circuit accepts 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC, with both maintained and impulse control signal types — so it works with a standard pushbutton, a PLC digital output, or a remote switch without an interposing relay. Local signalling includes a green LED for device ON, a flashing LED for device ready, tripped, or overheat conditions, plus a red LED for fault — enough status feedback to troubleshoot without opening the panel door. The toggle ON/OFF button on the front allows manual override, and the padlockable OFF position secures isolation for maintenance lockout. Depth is 77 mm, height 84 mm, IP20 finger-safe terminals — standard for enclosure mounting with a transparent door or cover. The Reflex iC60N integrates a control relay and an MCB into one package, which simplifies panel wiring and reduces component count compared to separate contactor and breaker combinations — a genuine space and labour saving if the 16 A rating fits your load.","metaTitle":"Schneider Electric A9C52416 Reflex iC60N MCB, 16 A, 4P, C Cu","metaDescription":"Schneider Electric A9C52416 Reflex iC60N integrated control circuit breaker, 16 A rated current, 4 poles, curve C, 20 kA breaking capacity at 240 V. Active production, DIN rail mou","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"117 mm","Height":"84 mm","IP Rating":"IP20","Application":"Control Distribution","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Control Signal Type":"Maintained Impulse","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9C52416/reflexi-c60n-16-a-4p-curve-c-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C52416/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C52416","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C52416 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}