{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C52425","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C52425","canonicalUrl":"https://aoctrl.com/schneider/A9C52425","factsUrl":"https://aoctrl.com/api/mcp/products/A9C52425","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N, integrated control circuit breaker, 25 A, 4 poles, curve C, 20 kA breaking capacity at 240 V AC.","salesMarkdown":"The Schneider Electric A9C52425 is a Reflex iC60N integrated control circuit breaker from the Acti9 range — a 25 A, 4-pole, curve C thermal-magnetic MCB with a remote-control toggle function. It combines overcurrent protection with a motorised switching element, so the same DIN-rail device handles both manual isolation and remote ON/OFF commands via a maintained or impulse control signal. The 4-pole version (4P) switches all phases and neutral, common for three-phase distribution in panel builds. Breaking capacity is 20 kA Icu at 220…240 V AC and 10 kA Icu at 380…415 V AC, both per EN/IEC 60947-2. That 20 kA figure at the common 230/240 V level means it can interrupt high fault currents on a strong utility feed without upstream fuses — useful for main incomer or sub-distribution positions where SCCR needs to stay high. Control circuit voltage options cover 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC — so the same breaker body works with a building-management 24 VDC PLC output or a conventional 230 VAC pushbutton circuit. The control signal type accepts both maintained (steady ON/OFF) and impulse (momentary-pulse) commands, matching most remote-control schemes. IP20 finger-safe terminals are standard for enclosed panel use. Occupies 13 x 9 mm pitches (117 mm wide) on the DIN rail — that's a 4-module width in the Acti9 footprint. Depth is 77 mm, height 84 mm. The fixed mounting mode means it clips directly onto the rail; no additional base or adapter needed. Local signalling includes a green LED for device ON, red LED for fault, flashing LED for trip/overheat, and a separate flashing LED for device-ready status — so a technician can read the breaker's state from across the cabinet without a meter.","metaTitle":"Schneider Electric A9C52425 Reflex iC60N 25A 4P Curve C MCB","metaDescription":"Schneider Electric A9C52425 Reflex iC60N integrated control MCB, 25 A, 4P, curve C, 20 kA breaking capacity at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"117 mm","Height":"84 mm","IP Rating":"IP20","Application":"Control Distribution","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Control Signal Type":"Maintained Impulse","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/A9C52425/reflex-ic60n-25-a-4p-curve-c-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C52425/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C52425","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C52425 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}