{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C61210","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C61210","canonicalUrl":"https://aoctrl.com/schneider/A9C61210","factsUrl":"https://aoctrl.com/api/mcp/products/A9C61210","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N, integrated control MCB, 10 A, 2P, curve B, 230 V AC, 20 kA Icu at 240 V AC.","salesMarkdown":"The Schneider Electric A9C61210 is a Reflex iC60N integrated control circuit breaker from the Acti9 range — a 10 A, 2-pole, curve B thermal-magnetic MCB with a built-in remote-control coil. It combines overcurrent protection with the ability to switch the load on and off via a pulse, a maintained signal, or a maintained very-low-voltage command, which saves panel space and wiring compared to a separate contactor and breaker. Rated 10 A with a B curve, so it trips magnetically between 3 and 5 times In — that's 30 to 50 A — making it a good fit for resistive and light inductive loads like contactor coils, control transformers, or small lighting circuits where you want fast fault clearance without nuisance trips from inrush. Breaking capacity is 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC, per EN/IEC 60947-2. Control circuit voltage options cover 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC, so it adapts to different control schemes without a separate interface relay. The control signal can be a pulse (momentary), a maintained signal, or a maintained very-low-voltage command, giving flexibility for remote or automated switching. This class of part — an integrated control circuit breaker — is used in control distribution panels where a single device needs to provide both overcurrent protection and remote on/off switching of a load. Typical applications include controlling contactor coils, solenoid valves, small motor starters, or lighting contactors in commercial and industrial power distribution.","metaTitle":"Schneider Electric A9C61210 Reflex iC60N, 10 A, 2P, Curve B","metaDescription":"Schneider Electric A9C61210 Reflex iC60N integrated control MCB, 10 A, 2 poles, curve B, 20 kA breaking capacity at 240 V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"81 mm","Colour":"White","Height":"84 mm","Curve code":"B","9 Mm Pitches":"9","Control type":"Toggle ON/OFF button Remote control by pulse Remote control by continuous command","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Flashing LED: device ready Red LED: fault Flashing LED: device overheat Green LED: device ON Flashing LED: device tripped","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"93 % at 40 °C","Device application":"Control Distribution","[In] rated current":"10 A","Control signal type":"Impulse Maintained very low voltage Maintained","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"N","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"2","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sa/en/product/A9C61210/reflex-ic60n-ti24-10-a-2p-curve-b-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C61210/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the A9C61210?","answer":"It is a 10 A, 2-pole, curve B thermal-magnetic MCB with a breaking capacity of 20 kA Icu at 240 V AC and 10 kA Icu at 415 V AC. Control voltages include 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC."},{"question":"What is the A9C61210's listed depth?","answer":"The depth is 77 mm."},{"question":"What is the A9C61210's range?","answer":"It belongs to the Schneider Electric Acti9 range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C61210","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C61210 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}