{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C61216","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C61216","canonicalUrl":"https://aoctrl.com/schneider/A9C61216","factsUrl":"https://aoctrl.com/api/mcp/products/A9C61216","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N, integrated control MCB, 16 A, 2P, curve B, thermal-magnetic trip, 20 kA breaking capacity at 230 V AC.","salesMarkdown":"The A9C61216 is a Schneider Electric Reflex iC60N integrated control circuit breaker from the Acti9 range — a 2-pole, 16 A unit with a B-curve thermal-magnetic trip. It combines overcurrent protection with local and remote ON/OFF switching, so it serves as both a branch-circuit protector and a load-break disconnect in one DIN-rail footprint. Control voltage options cover 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC, with impulse, maintained, or maintained very-low-voltage signal types — so it integrates with PLC digital outputs, pushbutton stations, or building-management controllers without an interposing relay. At 81 mm wide (9 x 9 mm pitches), it occupies two standard modular spaces — typical for a 2P MCB. IP20 finger-safe terminals (IEC 60529) suit enclosed panel installation; pollution degree 3 means it tolerates conductive dust in industrial cabinets. Padlockable in the OFF position via the built-in provision. Local signalling includes a green LED for ON state and flashing patterns for ready, tripped, and overheat conditions — useful for quick fault isolation on a live panel without metering.","metaTitle":"Schneider Electric A9C61216 Reflex iC60N, 16 A 2P Curve B MC","metaDescription":"Schneider Electric A9C61216 Reflex iC60N integrated control MCB, 16 A rated current, 2 poles, curve B, 20 kA breaking capacity at 230 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"81 mm","title":"A9C61216","Colour":"White","Height":"84 mm","Curve code":"B","description":"Reflex iC60N Ti24 16 A 2P curve B integrated control MCB","9 Mm Pitches":"9","Control type":"ON/OFF button Remote control by pulse Toggle Remote control by continuous command","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Green LED: device ON Flashing LED: device ready Flashing LED: device tripped Flashing LED: device overheat Red LED: fault","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"93 % at 40 °C","Device application":"Distribution Control","[In] rated current":"16 A","Control signal type":"Impulse Maintained Maintained very low voltage","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"N","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"2","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/mk/en/product/A9C61216/reflex-ic60n-ti24-16-a-2p-curve-b-integrated-control-mcb/"},"ai":{"faq":[{"question":"What is A9C61216's listed depth?","answer":"The listed depth is 77 mm."},{"question":"What is A9C61216's listed range?","answer":"It belongs to the Acti9 range."},{"question":"What compliance documentation does this brand provide for A9C61216?","answer":"The breaking capacity is certified to EN/IEC 60947-2. The IP20 rating conforms to IEC 60529. The manufacturer typically provides RoHS and REACH declarations for the Acti9 series, though specific certificates for this order code should be requested with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C61216","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C61216 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}