{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C61340","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C61340","canonicalUrl":"https://aoctrl.com/schneider/A9C61340","factsUrl":"https://aoctrl.com/api/mcp/products/A9C61340","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N integrated control MCB, A9C61340, 40 A, 3P, curve B, 20 kA breaking capacity, 230 V AC control.","salesMarkdown":"The 20 kA breaking capacity at 230 V AC (10 kA at 380–415 V) means it can safely interrupt a serious fault without upstream devices having to clear it. The control circuit accepts 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC, and supports maintained, impulse, or toggle commands. That's the flexibility you need when tying into a PLC output or a manual pushbutton station — no extra interface relay required for most common signal levels. Takes 11 x 9 mm pitches of rail space — call it 99 mm wide, 84 mm tall, 77 mm deep. That's a standard 3-module footprint for the Acti9 family, so it slots into a distribution board without surprises. IP20 rated, so it's for inside an enclosure, not on the wet side of the panel door. The tropicalisation class 2 adds some margin for high-humidity storage or operation — 93% RH at 40 °C is the listed limit. The B curve means the magnetic trip threshold is 3–5 times rated current (120–200 A for this 40 A unit). That's the standard choice for general distribution and control circuits — it won't false-trip on motor inrush, but it clears fast on a hard short. The thermal-magnetic trip technology is the workhorse for this class; no electronics to fail, no auxiliary power needed for the protection function. Electrical durability is 50,000 cycles under AC-1 resistive load at 50 Hz. That's the same as the mechanical endurance, so the switch mechanism is the limiting factor, not the contacts. For a control breaker that sees daily remote switching, that's a solid service life before you'd plan a replacement.","metaTitle":"Schneider Electric A9C61340 Reflex iC60N 40A 3P Curve B MCB","metaDescription":"Schneider Electric A9C61340 Reflex iC60N integrated control MCB, 40 A, 3-pole, curve B, 20 kA breaking capacity at 230 V AC. Active lifecycle, sourced to order. Fit for control and","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"99 mm","Height":"84 mm","IP Rating":"IP20","Application":"Control Distribution","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9C61340/reflex-ic60n-ti24-40-a-3p-curve-b-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C61340/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C61340","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C61340 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}