{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C61363","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C61363","canonicalUrl":"https://aoctrl.com/schneider/A9C61363","factsUrl":"https://aoctrl.com/api/mcp/products/A9C61363","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N Ti24 integrated control circuit breaker, A9C61363, 63 A, 3P, curve B, 20 kA Icu at 230 V AC.","salesMarkdown":"It combines overcurrent protection (thermal-magnetic trip, curve B) with remote switching capability in a single 3-pole unit rated 63 A. The 20 kA Icu at 230...240 V AC (10 kA at 380...415 V) per EN/IEC 60947-2 tells you it can handle substantial fault currents on a 230/400 V distribution network without upstream coordination headaches — the N breaking capacity code means it's the standard-duty version for this frame. This is not a plain MCB. The 'integrated control' function means it accepts remote control by pulse, toggle ON/OFF button, or continuous command (230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC control voltages). Fixed mounting mode, so no plug-in base to source separately. Padlockable in the OFF position (provision for padlocking), with a mechanical durability of 50,000 cycles and electrical durability of 50,000 cycles at AC-1. That's a solid 50 k-cycle life for resistive load switching — if you're cycling it daily under load, the electrical endurance number is the one that governs replacement intervals. Earth-leakage protection is handled by a separate block (not integrated), so if your design requires RCD functionality, you'll need to add an external Vigi iC60 module downstream. The local signalling — red LED for fault, flashing LED for tripped/ready/overheat, green LED for ON — gives a quick visual on status without opening the panel door.","metaTitle":"Schneider Electric A9C61363 Reflex iC60N Ti24, 63 A 3P curve","metaDescription":"Integrated control circuit breaker, 63 A, 3P, curve B, 20 kA at 230 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"99 mm","Height":"84 mm","IP Rating":"IP20","Application":"Distribution Control","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Insulation Voltage Ui":"500 V AC","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9C61363/reflex-ic60n-ti24-63-a-3p-curve-b-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C61363/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C61363","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C61363 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}