{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C61463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C61463","canonicalUrl":"https://aoctrl.com/schneider/A9C61463","factsUrl":"https://aoctrl.com/api/mcp/products/A9C61463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N, integrated control MCB, 63 A, 4P, curve B, 20 kA Icu at 240 V AC.","salesMarkdown":"The Schneider Electric A9C61463 is an integrated control circuit breaker from the Acti9 Reflex iC60N range, combining overcurrent protection with remote switching capability in a single 4-pole unit rated at 63 A with a B tripping curve. It offers a breaking capacity of 20 kA Icu at 220...240 V AC and 10 kA Icu at 380...415 V AC, per EN/IEC 60947-2, which means it can safely interrupt fault currents up to those levels without upstream damage in a distribution panel. The control circuit accepts multiple signal types — 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC — and supports impulse, maintained, or maintained very low voltage commands via the toggle or remote control. ## Where and how it mounts Electrical durability of 50,000 cycles under AC-1 resistive load at 50 Hz, matching the mechanical durability — this is a switching device rated for frequent operation, not just backup protection. Earth-leakage protection requires a separate block (Vigi iC60), so if ground-fault protection is needed, order the add-on module — not integrated here.","metaTitle":"Schneider Electric A9C61463 Reflex iC60N, 63 A 4P Curve B","metaDescription":"Schneider Electric A9C61463 Reflex iC60N integrated control MCB, 63 A, 4 poles, curve B, 20 kA breaking capacity at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"117 mm","title":"A9C61463","Colour":"White","Height":"84 mm","Curve code":"B","description":"Reflex iC60N Ti24 63 A 4P curve B integrated control MCB","9 Mm Pitches":"13","Control type":"Toggle Remote control by pulse Remote control by continuous command ON/OFF button","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Flashing LED: device ready Red LED: fault Flashing LED: device tripped Green LED: device ON Flashing LED: device overheat","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60N","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"93 % at 40 °C","Device application":"Control Distribution","[In] rated current":"63 A","Control signal type":"Impulse Maintained very low voltage Maintained","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"N","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"4","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9C61463/reflex-ic60n-ti24-63-a-4p-curve-b-integrated-control-mcb/"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9C61463?","answer":"It has a breaking capacity of 20 kA Icu at 220...240 V AC and 10 kA Icu at 380...415 V AC, conforming to EN/IEC 60947-2."},{"question":"What control voltages does the A9C61463 accept?","answer":"The control circuit accepts 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC, supporting impulse, maintained, or maintained very low voltage commands."},{"question":"Does the A9C61463 include earth-leakage protection?","answer":"No, earth-leakage protection requires a separate Vigi iC60 block — it is not integrated into this unit."},{"question":"What is the physical size and mounting of the A9C61463?","answer":"It measures 117 mm wide (13 module pitches), 84 mm high, and 77 mm deep, and mounts on a 35 mm symmetrical DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C61463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C61463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}