{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C62225","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C62225","canonicalUrl":"https://aoctrl.com/schneider/A9C62225","factsUrl":"https://aoctrl.com/api/mcp/products/A9C62225","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N Ti24, A9C62225, integrated control circuit breaker, 25 A, 2P, curve C, 20 kA breaking capacity at 230 V AC.","salesMarkdown":"The A9C62225 is a Reflex iC60N Ti24 integrated control circuit breaker from the Acti9 range, combining overcurrent protection with local and remote switching in a single DIN-rail module. It's a 25 A, 2-pole device with a C curve, rated for 230 V AC supply voltage and offering a 20 kA breaking capacity at 230...240 V AC per EN/IEC 60947-2. The thermal-magnetic trip unit handles both overload and short-circuit faults, while the integrated control allows ON/OFF toggle, remote pulse, or continuous command via the control circuit voltage options (230 V AC, 24 V AC, 48 V AC, 24 V DC, 48 V DC). This is a panel-building part for distribution and control circuits where you need to save space and wiring by combining a contactor and an MCB in one unit. At 380...415 V AC, the breaking capacity drops to 10 kA Icu, so if you're on a 400 V system, that's your number. The 2 poles protect both phase and neutral in a single-phase circuit, or two phases in a three-phase system. The 500 V AC rated insulation voltage (Ui) tells you the insulation system is rated for that voltage class, which is fine for standard 230/400 V networks. The fixed mounting mode means it's not a plug-in base; you wire it directly. At 81 mm wide (9 x 9 mm pitches), it takes up 9 module spaces on the rail, so plan your enclosure fill accordingly. Depth is 77 mm, height 84 mm. The padlockable handle (OFF position only) adds lockout/tagout capability for maintenance safety. The green LED for ON, red for fault, and flashing patterns for overheat/trip/ready give you status at a glance without needing a separate indicator. ## Durability and environmental ratings Electrical durability is rated at 50,000 cycles under AC-1 (resistive load) at 50 Hz — that's the expected life before the contacts wear out under normal switching. Mechanical durability matches at 50,000 cycles. Tropicalisation class 2 indicates it's treated for operation in high-humidity conditions (93% RH at 40 °C). Earth-leakage protection requires a separate block — this breaker doesn't include integral RCD protection.","metaTitle":"A9C62225 Reflex iC60N Ti24 25A 2P Curve C MCB","metaDescription":"A9C62225 Reflex iC60N Ti24 integrated control MCB, 25 A, 2P, curve C, 20 kA breaking capacity at 230 V AC. Active production. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"81 mm","title":"A9C62225","Colour":"White","Height":"84 mm","Curve code":"C","description":"Reflex iC60N Ti24 25 A 2P curve C integrated control MCB","9 Mm Pitches":"9","Control type":"ON/OFF button Toggle Remote control by pulse Remote control by continuous command","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Green LED: device ON Red LED: fault Flashing LED: device overheat Flashing LED: device tripped Flashing LED: device ready","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"93 % at 40 °C","Device application":"Distribution Control","[In] rated current":"25 A","Control signal type":"Maintained very low voltage Maintained Impulse","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"N","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"2","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$417.43","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9C62225/reflex-ic60n-ti24-25-a-2p-curve-c-integrated-control-mcb/"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9C62225 at different voltages?","answer":"At 220...240 V AC, the breaking capacity (Icu) is 20 kA per EN/IEC 60947-2. At 380...415 V AC, it drops to 10 kA Icu. For a 400 V system, use the 10 kA figure for coordination studies."},{"question":"What control voltage options does the A9C62225 support?","answer":"The control circuit voltage (Uc) can be 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC. The control signal type can be maintained (very low voltage or impulse) or maintained impulse."},{"question":"What is the physical size of the A9C62225 for panel layout?","answer":"Width is 81 mm (9 x 9 mm pitches), height is 84 mm, depth is 77 mm. It mounts on a 35 mm symmetrical DIN rail."},{"question":"Does the A9C62225 include earth-leakage protection?","answer":"No, earth-leakage protection requires a separate block. The breaker itself provides overcurrent and short-circuit protection only via its thermal-magnetic trip unit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C62225","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C62225 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}