{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C62240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C62240","canonicalUrl":"https://aoctrl.com/schneider/A9C62240","factsUrl":"https://aoctrl.com/api/mcp/products/A9C62240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N, integrated control MCB, 40 A, 2P, curve C, 20 kA Icu at 240 V AC, DIN-rail mount.","salesMarkdown":"The Schneider Electric A9C62240 is a Reflex iC60N integrated control circuit breaker from the Acti9 range, combining overcurrent protection with remote switching capability in a single 2-pole device rated at 40 A with a C curve. Rated 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC per EN/IEC 60947-2, so it handles substantial fault currents typical in commercial distribution panels while protecting downstream circuits. ## Control and integration Control circuit voltage options include 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC, giving flexibility for both mains-referenced and low-voltage control schemes. Supports toggle remote control by pulse ON/OFF button or by continuous command, as well as maintained or impulse control signals, so it can be wired into a PLC digital output or a manual pushbutton station. Local signalling via red and green LEDs indicates fault, device ON, overheat, tripped, and ready states, which helps during commissioning and troubleshooting without needing a separate indicator.","metaTitle":"Schneider Electric A9C62240 Reflex iC60N, 40 A, 2P, C Curve,","metaDescription":"Schneider Electric A9C62240 Reflex iC60N integrated control circuit breaker, 40 A, 2 poles, C curve, 20 kA breaking capacity at 240 V. Active production. Sourced to order via autho","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"81 mm","title":"A9C62240","Colour":"White","Height":"84 mm","Curve code":"C","description":"Reflex iC60N Ti24 40 A 2P curve C integrated control MCB","9 Mm Pitches":"9","Control type":"Toggle Remote control by pulse ON/OFF button Remote control by continuous command","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Red LED: fault Green LED: device ON Flashing LED: device overheat Flashing LED: device tripped Flashing LED: device ready","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"93 % at 40 °C","Device application":"Distribution Control","[In] rated current":"40 A","Control signal type":"Impulse Maintained very low voltage Maintained","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"N","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"2","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$249.66","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/A9C62240/reflex-ic60n-ti24-40-a-2p-curve-c-integrated-control-mcb/"},"ai":{"faq":[{"question":"What are the key ratings for the A9C62240?","answer":"Rated 40 A, 2 poles, C curve, with a breaking capacity of 20 kA Icu at 220–240 V AC and 10 kA Icu at 380–415 V AC per EN/IEC 60947-2. Control voltage options include 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC."},{"question":"What compliance documentation is available for the A9C62240?","answer":"The part carries EN/IEC 60947-2 certification for breaking capacity, IP20 per IEC 60529, and is rated for pollution degree 3. It is part of the Acti9 range with tropicalisation class 2. Specific RoHS/REACH/UL documentation is available upon request through the authorized channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C62240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C62240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}