{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C62263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C62263","canonicalUrl":"https://aoctrl.com/schneider/A9C62263","factsUrl":"https://aoctrl.com/api/mcp/products/A9C62263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N integrated control circuit breaker, A9C62263, 63 A, 2P, curve C, 20 kA breaking capacity at 230 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The Schneider Electric A9C62263 is a Reflex iC60N integrated control circuit breaker from the Acti9 range — a 2-pole, 63 A, curve C thermal-magnetic MCB with a built-in control interface, rated for 230 V AC networks at 50/60 Hz. It combines overcurrent protection with remote and local switching: the control type supports ON/OFF button, remote control by pulse, remote control by continuous command, and toggle — so it can be wired into a building management system or used as a local disconnect with a maintained or impulse signal. The breaking capacity is 20 kA Icu at 220...240 V AC and 10 kA Icu at 380...415 V AC, both conforming to EN/IEC 60947-2 — that means it can safely interrupt fault currents up to those levels without welding contacts or cascading failure upstream. Depth is 77 mm, height 84 mm — check your enclosure depth before committing the BOM line, especially in shallow gland-plate layouts. IP20 protection per IEC 60529 means it is touch-safe but not sealed against water ingress; suitable for dry indoor panels, not washdown zones. ## Control and signalling Control circuit voltage options cover 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC — so it can be driven from a standard AC control transformer or a 24 V DC PLC output without an interposing relay. Local signalling includes a flashing LED for device tripped, device ready, device overheat, and a green LED for device ON, plus a red LED for fault — useful for quick visual diagnostics on the panel door. A contact position indicator and provision for padlocking in the OFF position (padlockable) support lockout/tagout procedures during maintenance. ## Durability and environment Electrical durability is 50,000 cycles under AC-1 resistive load at 50 Hz; mechanical durability matches at 50,000 cycles — this is a switch rated for regular operation, not just backup protection. Tropicalisation class 2 and 93 % relative humidity at 40 °C mean it handles warm, humid panel environments without derating — relevant for SEA or coastal installations. Earth-leakage protection is handled by a separate block (not integrated), so if RCD functionality is needed, budget for an external Vigi module.","metaTitle":"Schneider Electric A9C62263 Reflex iC60N, 63 A, 2P, Curve C,","metaDescription":"Schneider Electric A9C62263 Reflex iC60N integrated control MCB. 63 A, 2P, curve C, 20 kA breaking capacity at 230 V AC. Active production. DIN rail mount. RFQ for landed cost.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"81 mm","title":"A9C62263","Colour":"White","Height":"84 mm","Curve code":"C","description":"Reflex iC60N Ti24 63 A 2P curve C integrated control MCB","9 Mm Pitches":"9","Control type":"ON/OFF button Remote control by pulse Remote control by continuous command Toggle","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Flashing LED: device tripped Flashing LED: device ready Red LED: fault Flashing LED: device overheat Green LED: device ON","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"93 % at 40 °C","Device application":"Distribution Control","[In] rated current":"63 A","Control signal type":"Maintained very low voltage Impulse Maintained","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"N","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"2","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$401.25","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9C62263/reflex-ic60n-ti24-63-a-2p-curve-c-integrated-control-mcb/"},"ai":{"faq":[{"question":"What are the key ratings for the A9C62263?","answer":"It is a 63 A, 2-pole, curve C thermal-magnetic MCB with a breaking capacity of 20 kA Icu at 230 V AC and 10 kA Icu at 415 V AC, rated for 230 V AC networks at 50/60 Hz."},{"question":"What control voltages does the A9C62263 accept?","answer":"The control circuit accepts 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC — covering both AC and DC control signals from typical panel supplies or PLC outputs."},{"question":"Does the A9C62263 include earth-leakage protection?","answer":"No, earth-leakage protection is handled by a separate block — the Reflex iC60N itself provides overcurrent protection only."},{"question":"What is the mounting method for the A9C62263?","answer":"It mounts on a 35 mm symmetrical DIN rail with a fixed mounting mode, occupying 81 mm (9 pitches of 9 mm) of rail width."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C62263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C62263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}