{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C62416","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C62416","canonicalUrl":"https://aoctrl.com/schneider/A9C62416","factsUrl":"https://aoctrl.com/api/mcp/products/A9C62416","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N, A9C62416, integrated control MCB, 16 A, 4P, curve C, thermal-magnetic, 20 kA breaking capacity.","salesMarkdown":"It combines overcurrent protection (MCB function) with local and remote switching control in a single 4-pole unit rated at 16 A with a C trip curve. The thermal-magnetic trip unit handles overloads and short-circuits, while the control section accepts multiple signal types: impulse (pulse), maintained (continuous command), and maintained very low voltage, all at 230 V AC, 24 V AC/DC, or 48 V AC/DC control voltages. Breaking capacity is 20 kA Icu at 220...240 V AC and 10 kA Icu at 380...415 V AC, per EN/IEC 60947-2. At 16 A rated current, it fits a 16 A feeder or a group of loads summing to that figure. Electrical durability is 50,000 cycles under AC-1 (resistive) load at 50 Hz, with matching mechanical durability. That's a solid service life for a switching device that will see daily on/off cycles from remote commands or local toggle operation. ## Control and integration At 13 x 9 mm pitches (117 mm wide for 4 poles), it occupies four modular spaces. The fixed mounting mode means it stays put once snapped onto the rail. Control options include a local toggle ON/OFF button, remote control by pulse (impulse), remote control by continuous command (maintained), and a maintained very low voltage signal. This flexibility lets an integrator wire it for momentary pushbutton control from a PLC digital output, or for sustained signal from a safety relay or manual switch. Local signalling uses a multi-colour LED: green for ON, flashing for tripped or ready or overheat, red for fault. The contact position indicator gives a visual confirmation of the main contact state independent of the LED. IP20 protection means it's touch-safe but not sealed against moisture — standard for indoor panel installation. Earth-leakage protection requires a separate block (Vigi or similar), not integrated.","metaTitle":"Schneider Electric A9C62416 Reflex iC60N, 16A 4P C-Curve MCB","metaDescription":"Schneider Electric A9C62416 Reflex iC60N integrated control MCB. 16A rated, 4 poles, curve C. Breaking capacity 20 kA at 240 V AC. DIN rail mount. Active production. RFQ for quanti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"117 mm","title":"A9C62416","Colour":"White","Height":"84 mm","Curve code":"C","description":"Reflex iC60N Ti24 16 A 4P curve C integrated control MCB","9 Mm Pitches":"13","Control type":"Remote control by pulse Remote control by continuous command Toggle ON/OFF button","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Flashing LED: device tripped Green LED: device ON Flashing LED: device ready Flashing LED: device overheat Red LED: fault","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60N","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"93 % at 40 °C","Device application":"Control Distribution","[In] rated current":"16 A","Control signal type":"Impulse Maintained Maintained very low voltage","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"N","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"4","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$345.24","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9C62416/reflex-ic60n-ti24-16-a-4p-curve-c-integrated-control-mcb/"},"ai":{"faq":[{"question":"What breaking capacity does this breaker have?","answer":"20 kA Icu at 220...240 V AC and 10 kA Icu at 380...415 V AC, both per EN/IEC 60947-2."},{"question":"What control voltages does it accept?","answer":"230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC — five control voltage options covering most industrial and commercial control circuits."},{"question":"How does the control work — can a PLC drive it?","answer":"Yes. It accepts impulse (pulse), maintained (continuous), and maintained very low voltage signals. A PLC digital output rated for the chosen control voltage can drive the remote input directly."},{"question":"Does this include earth-leakage (RCD) protection?","answer":"No. Earth-leakage protection requires a separate block (Vigi or compatible) added downstream or as an accessory. The breaker itself is overcurrent-only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C62416","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C62416 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}