{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C63316","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C63316","canonicalUrl":"https://aoctrl.com/schneider/A9C63316","factsUrl":"https://aoctrl.com/api/mcp/products/A9C63316","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60N Ti24, 16 A, 3P, curve D, 20 kA Icu at 230 V AC, integrated control MCB.","salesMarkdown":"The Schneider Electric A9C63316 is a Reflex iC60N Ti24 integrated control circuit breaker from the Acti9 range — a 3-pole, 16 A thermal-magnetic MCB with a D curve, designed for distribution and control applications on AC networks at 50/60 Hz. Breaking capacity is 20 kA Icu at 220…240 V AC and 10 kA Icu at 380…415 V AC, both per EN/IEC 60947-2 — enough for most industrial panel secondary distribution. ## Control and integration This isn't just a breaker — it's an integrated control device with an ON/OFF button and remote control capability via pulse or continuous command, using a separate control voltage (230 V AC, 24 V AC/DC, or 48 V AC/DC). Mounts on a 35 mm symmetrical DIN rail (fixed mounting), taking 11 × 9 mm pitches of panel space — 99 mm wide, 84 mm high, 77 mm deep. IP20 rated per IEC 60529, so it's for dry indoor enclosures only; pollution degree 3 suits industrial environments with conductive pollution. Earth-leakage protection is handled by a separate block (not built in), so if you need RCD functionality, plan for an add-on Vigi module.","metaTitle":"Schneider Electric A9C63316 Reflex iC60N Ti24 16 A 3P curve","metaDescription":"Schneider Electric A9C63316 Reflex iC60N integrated control MCB, 16 A, 3P, curve D, 20 kA breaking capacity at 230 V AC, DIN rail mount, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"99 mm","Colour":"White","Height":"84 mm","Curve code":"D","9 Mm Pitches":"11","Control type":"ON/OFF button Toggle Remote control by pulse Remote control by continuous command","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Red LED: fault Flashing LED: device overheat Green LED: device ON Flashing LED: device ready Flashing LED: device tripped","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60N","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"93 % at 40 °C","Device application":"Distribution Control","[In] rated current":"16 A","Control signal type":"Maintained very low voltage Impulse Maintained","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"N","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"3","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9C63316/reflex-ic60n-ti24-16-a-3p-curve-d-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C63316/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this MCB?","answer":"16 A rated current, 3-pole, D curve, 20 kA Icu at 230 V AC (10 kA at 415 V AC) per EN/IEC 60947-2, with a 230 V AC control circuit voltage option."},{"question":"What control voltages does it accept?","answer":"The control circuit accepts 230 V AC, 24 V AC/DC, and 48 V AC/DC — three options covering most panel control schemes."},{"question":"Does it include earth-leakage protection?","answer":"No — earth-leakage protection requires a separate block (Vigi module); this is the thermal-magnetic MCB only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C63316","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C63316 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}