{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C63425","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C63425","canonicalUrl":"https://aoctrl.com/schneider/A9C63425","factsUrl":"https://aoctrl.com/api/mcp/products/A9C63425","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Reflex iC60N Ti24, A9C63425, integrated control circuit breaker, 25 A, 4 poles, curve D, 20 kA Icu at 230 V AC.","salesMarkdown":"The Schneider Electric A9C63425 is a Reflex iC60N Ti24 integrated control circuit breaker from the Acti9 range, combining overcurrent protection with remote switching in a single 4-pole package. The part is certified to EN/IEC 60947-2 and carries a 20 kA Icu breaking capacity at 230 V AC, dropping to 10 kA at 380–415 V AC. That SCCR headroom is enough for most distribution sub-panels in industrial control cabinets; the 500 V AC rated insulation voltage (Ui) confirms it lives on 400 V three-phase networks without derating. ## Control and signalling — what the Ti24 suffix means Ti24 denotes the control interface: the breaker accepts a maintained or pulsed low-voltage signal (24 V AC/DC, 48 V AC/DC, or 230 V AC) on its integrated control coil, so a PLC or remote pushbutton can toggle the main contacts without a separate contactor. Local status is visible through the green ON LED, red fault LED, and flashing indicators for tripped, overheat, and ready states. The control circuit voltage options (24 V AC/DC, 48 V AC/DC, 230 V AC) let you match the panel's existing control voltage — no extra transformer for the coil. The fixed mounting mode and 13 × 9 mm pitch footprint (117 mm wide, 84 mm high, 77 mm deep) occupy four modular spaces in the enclosure. Tropicalisation class 2 means it withstands 93 % RH at 40 °C, so coastal or unconditioned plant rooms are fine. The padlockable OFF position (provision for padlocking) satisfies lockout/tagout requirements without an accessory.","metaTitle":"Schneider A9C63425 Reflex iC60N Ti24 25A 4P Curve D MCB","metaDescription":"Schneider Electric Reflex iC60N Ti24 integrated control MCB, 25 A, 4P, curve D, 20 kA breaking capacity at 230 V AC. Active production. DIN rail. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"117 mm","Height":"84 mm","IP Rating":"IP20","Application":"Distribution Control","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$389.64","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9C63425/reflex-ic60n-ti24-25-a-4p-curve-d-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C63425/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C63425","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C63425 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}