{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C64340","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C64340","canonicalUrl":"https://aoctrl.com/schneider/A9C64340","factsUrl":"https://aoctrl.com/api/mcp/products/A9C64340","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60H, integrated control circuit breaker, 40 A, 3P, curve B, thermal-magnetic trip, 30 kA breaking capacity.","salesMarkdown":"It is rated at 40 A with a B-curve thermal-magnetic trip characteristic, making it suitable for protecting and controlling resistive or lightly inductive loads in distribution panels. The 3-pole unit offers a breaking capacity of 30 kA Icu at 220–240 V AC and 15 kA Icu at 380–415 V AC, certified to EN/IEC 60947-2. Control is via toggle, remote pulse, or continuous command, with a choice of 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC control voltages. The green LED signals device-on; flashing LEDs indicate tripped, overheat, fault, or ready states, which helps a field technician diagnose a tripped breaker without opening the panel door. IP20 finger protection per IEC 60529 is adequate for enclosed panel use but not for exposed or washdown environments. Dimensions are 99 mm wide, 84 mm high, and 77 mm deep. The depth is the projection from the DIN rail — relevant when planning gland-plate clearance or cover depth in a shallow enclosure.","metaTitle":"Schneider Electric A9C64340 Reflex iC60H, 40 A, 3P, Curve B","metaDescription":"Schneider Electric A9C64340 Reflex iC60H integrated control circuit breaker, 40 A rated, 3-pole, curve B, 30 kA breaking capacity at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"99 mm","Colour":"White","Height":"84 mm","Curve code":"B","9 Mm Pitches":"11","Control type":"Toggle Remote control by pulse Remote control by continuous command ON/OFF button","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Green LED: device ON Flashing LED: device tripped Flashing LED: device overheat Red LED: fault Flashing LED: device ready","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60H","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"93 % at 40 °C","Device application":"Control Distribution","[In] rated current":"40 A","Control signal type":"Maintained Impulse Maintained very low voltage","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"H","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"3","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9C64340/reflex-ic60h-ti24-40-a-3p-curve-b-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C64340/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The headline ratings are 40 A rated current (In), B-curve trip characteristic, 3-pole configuration, and a breaking capacity of 30 kA at 240 V AC / 15 kA at 415 V AC per IEC 60947-2. Control voltage options include 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C64340","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C64340 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}