{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C64416","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C64416","canonicalUrl":"https://aoctrl.com/schneider/A9C64416","factsUrl":"https://aoctrl.com/api/mcp/products/A9C64416","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60H Ti24, A9C64416, integrated control MCB, 16 A, 4P, curve B, 30 kA Icu at 230 V AC.","salesMarkdown":"## Integrated control circuit breaker for panel-based distribution The Schneider Electric A9C64416 is a Reflex iC60H Ti24 integrated control circuit breaker from the Acti9 range, combining overcurrent protection with local and remote switching in a single 4-pole unit. Rated 16 A with a B curve, it is designed for control distribution panels where you need both a disconnecting means and motor/load switching under one DIN-rail footprint. The 30 kA Icu at 230 V AC (15 kA at 415 V AC) per EN/IEC 60947-2 tells you this breaker can interrupt a fault up to that level without welding its contacts — critical for panel SCCR coordination. Control voltage options span 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC, with three control signal types (maintained very low voltage, impulse, maintained). This means the same part works with a PLC digital output (24 V DC impulse) or a panel pushbutton (230 V AC maintained) — no separate contactor needed for the switching function. Integrated control circuit breakers like the Reflex iC60 are used in control distribution panels to combine branch circuit protection with local on/off switching and remote control via a pulse or maintained signal. Typical applications include HVAC control panels, lighting contactor replacement, pump control, and small machine control where a separate contactor and breaker would take up twice the DIN-rail space.","metaTitle":"Schneider Electric A9C64416 Reflex iC60H Ti24 16A 4P Curve B","metaDescription":"Schneider Electric A9C64416 Reflex iC60H integrated control MCB, 16 A rated current, 4 poles, curve B, 30 kA breaking capacity at 230 V AC. Active production. RFQ for project deliv","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"117 mm","Height":"84 mm","IP Rating":"IP20","Application":"Control Distribution","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/id/en/product/A9C64416/reflex-ic60h-ti24-16-a-4p-curve-b-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C64416/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C64416","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C64416 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}