{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C64425","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C64425","canonicalUrl":"https://aoctrl.com/schneider/A9C64425","factsUrl":"https://aoctrl.com/api/mcp/products/A9C64425","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60H Ti24, integrated control circuit breaker, 25 A, 4P, curve B, 30 kA breaking capacity, 230 V AC control.","salesMarkdown":"It combines overcurrent protection with remote switching in a single 4-pole unit, rated 25 A with a B trip curve. The thermal-magnetic trip unit handles overload and short-circuit protection, while the integrated control coil allows remote ON/OFF via a maintained or pulse signal — 230 V AC, 24 V AC, 48 V AC, or 24/48 V DC control voltages are supported. This avoids a separate contactor and MCB in the same circuit, saving DIN-rail space and wiring. Breaking capacity is 30 kA Icu at 230 V AC and 15 kA Icu at 415 V AC, both per EN/IEC 60947-2. The 15 kA at 415 V covers three-phase supplies common in industrial panels. The control coil accepts several voltages — 230 V AC, 24 V AC, 48 V AC, 24 V DC, 48 V DC — and responds to maintained, impulse, or toggle signals. That flexibility lets a panel builder wire it to a PLC digital output, a pushbutton station, or a building management system without an interposing relay. The local signalling includes a flashing LED for trip or overheat, a red fault LED, and a green ON LED — useful for quick diagnostics without opening the panel door. Electrical durability is 50,000 cycles under AC-1 (resistive) load, matching the mechanical durability of 50,000 cycles. For a combined protection-and-switching device, that cycle life is adequate for daily ON/OFF control in HVAC or lighting circuits — not for high-frequency motor starting, where a dedicated contactor would be specified. The 4-pole body occupies 13 modules of 9 mm pitch — that is 117 mm width — plus 84 mm height and 77 mm depth. Earth-leakage protection is handled by a separate block (not integrated), so if RCD protection is needed, you add a Vigi iC60 module downstream on the same DIN rail. The breaker itself protects all 4 poles; the neutral pole is switched and protected.","metaTitle":"Schneider Electric A9C64425 Reflex iC60H Ti24 25 A 4P curve","metaDescription":"Schneider Electric A9C64425 Reflex iC60H integrated control MCB, 25 A rated current, 4 poles, curve B, 30 kA breaking capacity at 230 V AC. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"117 mm","Colour":"White","Height":"84 mm","Curve code":"B","9 Mm Pitches":"13","Control type":"Remote control by continuous command Remote control by pulse ON/OFF button Toggle","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Flashing LED: device overheat Flashing LED: device tripped Red LED: fault Green LED: device ON Flashing LED: device ready","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"93 % at 40 °C","Device application":"Distribution Control","[In] rated current":"25 A","Control signal type":"Maintained very low voltage Impulse Maintained","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"H","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"4","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/mk/en/product/A9C64425/reflex-ic60h-ti24-25-a-4p-curve-b-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C64425/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to A9C64425 in this family?","answer":"Within the Reflex iC60H range, the primary variant difference is the rated current and curve. For a 25 A 4P B-curve unit, the A9C64425 is the standard offering. A C-curve version at the same current (for motor or transformer loads) would be a different order code — the B curve here is for resistive/general loads. No direct pin-compatible second-source exists outside the Acti9 family; the Reflex iC60H is a proprietary integrated design combining a breaker and remote control coil in one housing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C64425","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C64425 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}