{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C65310","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C65310","canonicalUrl":"https://aoctrl.com/schneider/A9C65310","factsUrl":"https://aoctrl.com/api/mcp/products/A9C65310","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60H Ti24, integrated control circuit breaker, 10 A, 3P, curve C, 30 kA breaking capacity at 230 V AC.","salesMarkdown":"Rated 10 A on a 3-pole, curve C trip characteristic, it is designed for control and distribution circuits where you need to open and close the load remotely while still providing overcurrent and short-circuit protection. The remote control accepts multiple command types: maintained (continuous), impulse (pulse), or maintained very-low-voltage signals, with control voltages available at 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC. This flexibility lets it integrate into both conventional AC control circuits and DC-based automation systems without an interposing relay. Breaking capacity is the headline protective rating: 30 kA Icu at 220–240 V AC and 15 kA Icu at 380–415 V AC, both per EN/IEC 60947-2. The 'H' in iC60H denotes this higher breaking capacity variant. Rated insulation voltage (Ui) is 500 V AC, which sets the maximum voltage the internal insulation system can withstand continuously. This exceeds the 230 V control supply and the 400 V class network, so the part is suitable for 3-phase panels up to 400 V phase-to-phase without derating the insulation path. Curve C means the magnetic trip operates at 5 to 10 times In (50–100 A for this 10 A unit), making it appropriate for circuits with moderate inrush — think control transformers, contactor coils, or small motor starters — rather than purely resistive loads (curve B) or high-inrush transformers (curve D). Electrical durability is rated at 50,000 cycles under AC-1 (resistive) load at 50 Hz, matching the mechanical endurance of 50,000 cycles. For a combined control-and-protection device this is a solid service life; if your application requires frequent switching at rated current, this figure governs the replacement interval. The unit mounts on a 35 mm symmetrical DIN rail, occupies 11 x 9 mm pitches (99 mm width), and is IP20 finger-safe per IEC 60529 — standard for enclosed panel installation. ## Integration and wiring considerations Earth-leakage protection is handled by a separate block (not integrated), so if ground-fault protection is required on this circuit, you will need to add a compatible Vigi iC60 or similar RCD module downstream or upstream. The Reflex iC60H itself provides only overcurrent and short-circuit protection. Local signalling uses a green LED for device ON, a flashing LED for tripped condition, and a red LED for fault — useful for panel walk-downs. The contact position indicator gives visual confirmation of the main contact state without needing to meter the load side. Provision for padlocking in the OFF position allows lockout/tagout compliance per standard safety practices. The padlock hasp accepts a standard padlock shackle to secure the breaker in the off state during maintenance.","metaTitle":"Schneider Electric A9C65310 Reflex iC60H Ti24 10A 3P Curve C","metaDescription":"Schneider Electric A9C65310 Reflex iC60H integrated control circuit breaker, 10A rated current, 3 poles, curve C, breaking capacity 30kA at 230V AC. Active production, sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"99 mm","Height":"84 mm","IP Rating":"IP20","Application":"Control Distribution","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nz/en/product/A9C65310/reflex-ic60h-ti24-10-a-3p-curve-c-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C65310/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C65310","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C65310 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}