{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C65410","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C65410","canonicalUrl":"https://aoctrl.com/schneider/A9C65410","factsUrl":"https://aoctrl.com/api/mcp/products/A9C65410","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60H Ti24, integrated control circuit breaker, 10 A, 4P, curve C, 30 kA Icu at 220-240 V AC.","salesMarkdown":"It's rated 10 A, 4 poles, curve C, and carries a 30 kA Icu breaking capacity at 220-240 V AC (15 kA at 380-415 V AC) per EN/IEC 60947-2. The thermal-magnetic trip unit handles the protection side; the control side accepts maintained or impulse commands at 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC. For a panel with a prospective fault current under that threshold, this breaker clears the fault without needing an upstream fuse or larger breaker to protect it. The 15 kA rating at 380-415 V AC is the same figure for three-phase networks; if your line-to-line fault current exceeds that, you need to coordinate with a current-limiting device upstream. It avoids nuisance tripping from inrush currents that a curve B would catch, but trips faster on high faults than a curve D would. The neutral pole is protected (switched and monitored), not just a solid link. That matters for TN-S or TN-C-S systems where you need full isolation on all conductors during maintenance. Fixed mounting mode, so it clips in place and stays put. The 117 mm width (13 x 9 mm pitches) and 84 mm height fit a standard modular device footprint; the 77 mm depth leaves room for wiring behind the DIN rail. The control interface supports three command types: remote control by pulse, remote control by continuous command, and local ON/OFF toggle. That flexibility lets you wire it to a PLC digital output for automated load shedding, or to a manual pushbutton for local override. The green/red/flashing LED signalling gives immediate visual feedback on device state, trip, and overheat conditions — useful during commissioning and fault finding.","metaTitle":"Schneider Electric A9C65410 Reflex iC60H Ti24 10A 4P Curve C","metaDescription":"Schneider Electric A9C65410 Reflex iC60H integrated control MCB, 10A, 4P, curve C, 30kA breaking capacity at 220-240V AC. Active production. DIN rail mount. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"117 mm","Height":"84 mm","IP Rating":"IP20","Application":"Control Distribution","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9C65410/reflex-ic60h-ti24-10-a-4p-curve-c-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C65410/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C65410","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C65410 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}