{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C66216","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C66216","canonicalUrl":"https://aoctrl.com/schneider/A9C66216","factsUrl":"https://aoctrl.com/api/mcp/products/A9C66216","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60H Ti24, integrated control MCB, 16 A, 2P, curve D, 30 kA breaking capacity.","salesMarkdown":"The Schneider Electric A9C66216 is a Reflex iC60H Ti24 integrated control circuit breaker — a thermal-magnetic MCB with a built-in remote control module, rated 16 A, 2 poles, curve D, from the Acti9 range. The 30 kA breaking capacity at 230 V AC (15 kA at 415 V) per EN/IEC 60947-2 means it can safely interrupt high fault currents without upstream cascading — a key spec for panel SCCR compliance. ## Control and integration The Ti24 control module accepts multiple signal types: maintained very low voltage, impulse, or maintained 230 V AC, 24 V AC/DC, or 48 V AC/DC — so the same part works with a remote pushbutton, PLC digital output, or building management contact. Local signalling via a flashing/green/red LED indicates device ready, tripped, overheat, or ON — useful for quick fault isolation without a meter. ## Environmental and durability Electrical durability of 50,000 cycles in AC-1 (resistive load) and matching mechanical durability — aligns with typical panel life for a controlled distribution circuit. IP20 finger-safe terminals per IEC 60529; earth-leakage protection requires a separate Vigi block (not integrated).","metaTitle":"Schneider Electric A9C66216 Reflex iC60H Ti24 16A 2P curve D","metaDescription":"Schneider Electric A9C66216 Reflex iC60H integrated control MCB, 16A, 2P, curve D, 30kA breaking capacity at 230V AC. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"77 mm","Range":"Acti9","Width":"81 mm","title":"A9C66216","Colour":"White","Height":"84 mm","Curve code":"D","description":"Reflex iC60H Ti24 16 A 2P curve D integrated control MCB","9 Mm Pitches":"9","Control type":"ON/OFF button Remote control by pulse Toggle Remote control by continuous command","Network type":"AC","Product name":"Reflex iC60","Mounting mode":"Fixed","Tropicalisation":"2","lifecycle_stage":"current","Local signalling":"Flashing LED: device ready Flashing LED: device tripped Flashing LED: device overheat Green LED: device ON Red LED: fault","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3","Breaking capacity":"30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"Reflex iC60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"93 % at 40 °C","Device application":"Control Distribution","[In] rated current":"16 A","Control signal type":"Maintained very low voltage Impulse Maintained","Trip unit technology":"Thermal-magnetic","Electrical durability":"AC-1: 50000 cycles AC 50 Hz","Mechanical durability":"50000 cycles","Breaking capacity code":"H","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"2","Product or component type":"Integrated control circuit breaker","[Us] rated supply voltage":"230 V AC at 50/60 Hz","Contact position indicator":"Yes","Locking options description":"Padlock in OFF position","[Uc] control circuit voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","[Ui] rated insulation voltage":"500 V AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/mk/en/product/download-pdf/A9C66216?filename=Schneider+Electric_EcoStruxure-I-O-Smart-Link_A9C66216.pdf', 'path_name': '0bf83c48c8abafd92f8b55d4d7f2b8fc.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/0bf83c48c8abafd92f8b55d4d7f2b8fc.pdf', 'status': 1}","sourceUrl":"https://www.se.com/mk/en/product/A9C66216/reflex-ic60h-ti24-16-a-2p-curve-d-integrated-control-mcb/"},"ai":{"faq":[{"question":"What are the control voltage options for this Reflex iC60H?","answer":"The Ti24 module accepts 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC — select the signal type (maintained, impulse, or maintained very low voltage) to match your remote control scheme."},{"question":"What does the 30 kA breaking capacity mean for panel design?","answer":"It means the breaker can interrupt a 30 kA fault at 230 V AC without failing — that's the Icu per EN/IEC 60947-2, so it supports high available fault current on the distribution bus without requiring a current-limiting upstream device."},{"question":"What is the physical size of the A9C66216?","answer":"It measures 84 mm high, 81 mm wide, and 77 mm deep — standard 2-pole MCB footprint on 35 mm DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C66216","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C66216 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}