{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C66216","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C66216","canonicalUrl":"https://aoctrl.com/schneider/A9C66216","factsUrl":"https://aoctrl.com/api/mcp/products/A9C66216","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60H Ti24, integrated control MCB, 16 A, 2P, curve D, 30 kA breaking capacity.","salesMarkdown":"The Schneider Electric A9C66216 is a Reflex iC60H Ti24 integrated control circuit breaker — a thermal-magnetic MCB with a built-in remote control module, rated 16 A, 2 poles, curve D, from the Acti9 range. The 30 kA breaking capacity at 230 V AC (15 kA at 415 V) per EN/IEC 60947-2 means it can safely interrupt high fault currents without upstream cascading — a key spec for panel SCCR compliance. ## Control and integration The Ti24 control module accepts multiple signal types: maintained very low voltage, impulse, or maintained 230 V AC, 24 V AC/DC, or 48 V AC/DC — so the same part works with a remote pushbutton, PLC digital output, or building management contact. Local signalling via a flashing/green/red LED indicates device ready, tripped, overheat, or ON — useful for quick fault isolation without a meter. ## Environmental and durability Electrical durability of 50,000 cycles in AC-1 (resistive load) and matching mechanical durability — aligns with typical panel life for a controlled distribution circuit. IP20 finger-safe terminals per IEC 60529; earth-leakage protection requires a separate Vigi block (not integrated).","metaTitle":"Schneider Electric A9C66216 Reflex iC60H Ti24 16A 2P curve D","metaDescription":"Schneider Electric A9C66216 Reflex iC60H integrated control MCB, 16A, 2P, curve D, 30kA breaking capacity at 230V AC. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"81 mm","Height":"84 mm","IP Rating":"IP20","Application":"Control Distribution","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/mk/en/product/A9C66216/reflex-ic60h-ti24-16-a-2p-curve-d-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C66216/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C66216","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C66216 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}