{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9C66316","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9C66316","canonicalUrl":"https://aoctrl.com/schneider/A9C66316","factsUrl":"https://aoctrl.com/api/mcp/products/A9C66316","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Reflex iC60H, A9C66316, integrated control circuit breaker, 16 A, 3P, curve D, thermal-magnetic trip, 30 kA breaking capacity.","salesMarkdown":"The thermal-magnetic trip unit handles both slow thermal overloads and fast magnetic shorts. The remote control capability is the headline feature here — it accepts a maintained or impulse control signal (230 V AC, 24 V AC/DC, 48 V AC/DC) so you can open or close the breaker from a PLC output, a pushbutton, or a building management system. This makes it a fit for applications where you want to remotely shed a non-critical load or reset a circuit without sending someone to the panel. The local signaling — green LED for ON, flashing red for fault, flashing for device ready or overheat — gives you a quick visual on the panel door without needing a separate indicator. Breaking capacity is 30 kA Icu at 220-240 V AC and 15 kA Icu at 380-415 V AC, both per EN/IEC 60947-2. That 30 kA at 240 V is the number that matters for most commercial and light industrial panels in North America on a 240/120 V split-phase or 208Y/120 V system — it means this breaker can safely interrupt a fault current up to 30,000 amps without welding its contacts or failing catastrophically. At 400 V three-phase (common in European and industrial plants), the 15 kA rating still covers a lot of service-entrance and sub-panel scenarios. The IP20 finger-safe terminals are fine for enclosed panels; if you need washdown protection, you'd put this behind a sealed door.","metaTitle":"Schneider Electric A9C66316 Reflex iC60H, 16 A, 3P, Curve D,","metaDescription":"Schneider Electric A9C66316 Reflex iC60H integrated control circuit breaker, 16 A rated current, 3 poles, curve D, 30 kA breaking capacity at 240 V AC. Active production. DIN rail","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"77 mm","Width":"99 mm","Height":"84 mm","IP Rating":"IP20","Application":"Control Distribution","Coil Voltage":"230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3","Breaking Capacity":"30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC","Electrical Life Cycles":"AC-1: 50000 cycles AC 50 Hz","Mechanical Life Cycles":"50000 cycles","Main Product Or Component Type":"Integrated control circuit breaker"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9C66316/reflex-ic60h-ti24-16-a-3p-curve-d-integrated-control-mcb/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9C66316/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9C66316","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9C66316 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}