{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D01845","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D01845","canonicalUrl":"https://aoctrl.com/schneider/A9D01845","factsUrl":"https://aoctrl.com/api/mcp/products/A9D01845","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H RCBO, A9D01845, 1P+N, 45 A, Type C, 10 kA, 10 mA earth leakage, thermal-magnetic, plug-on.","salesMarkdown":"It integrates earth-leakage detection and thermal-magnetic overcurrent tripping into one device, saving a DIN-rail position compared to separate MCB + RCCB. Breaking capacity is 10 kA Icn at 240 V AC, 50/60 Hz, conforming to IEC 61009-2-2. ## Earth-leakage protection Integrated earth-leakage protection at 10 mA sensitivity — a high-sensitivity trip designed for circuits where additional shock protection is specified (e.g., socket outlets in bathrooms, construction sites, or circuits supplying hand-held equipment). The 10 mA threshold catches leakage currents well below the 30 mA standard, reducing the risk of ventricular fibrillation. Plug-on mounting onto Isobar A or Isobar B distribution boards. The 18 mm width (2 × 9 mm pitches) fits standard modular enclosures. Screw-clamp terminals with tightening torque 3.5 N·m top, 2 N·m bottom. Wire stripping length 14 mm top, 13 mm bottom. IP20 finger-safe, IP40 within the modular enclosure.","metaTitle":"Schneider Electric A9D01845 Acti9 iC60 RCBO, 45 A, 10 kA, 10","metaDescription":"Schneider Electric A9D01845 Acti9 iC60H RCBO. 45 A rated current, 10 kA breaking capacity, 10 mA earth leakage, Type C curve. Active production. Sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"72 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"110 mm","Standards":"BS EN 61009-1 IEC 61009-1 IEC 61009-2-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Plug-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"Fault indication ON/OFF indication","Mounting support":"Isobar A Isobar B","Neutral position":"Left","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IEC 61009-2-2","Device short name":"iC60H RCBO PoN","Network frequency":"50/60 Hz","Poles description":"1P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top 2 N.m bottom","[In] rated current":"45 A at 50 °C","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top connection 13 mm for bottom connection","Connections - terminals":"Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...10 mm² flexible Screw clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (bottom) 1...16 mm² rigid Plug-on neutral (upstream)","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"10 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Electrical insulation class":"Class II","Locking options description":"Padlock in on or off position","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 240 V AC 50/60 Hz conforming to IEC 61009-2-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D01845/acti9-ic60h-rcbo-plug-on-neutral-1p+ns-45a-c-10000a-10ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D01845/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9D01845 and how do I get a price?","answer":"The A9D01845 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to A9D01845 in this component family?","answer":"Within the Acti9 iC60 range, the primary variant difference is the rated current and earth-leakage sensitivity. The A9D01845 is a 45 A, 10 mA unit. A direct 45 A sibling with 30 mA sensitivity (e.g., A9D01846) shares the same mechanical footprint and breaking capacity but trips at a higher leakage threshold — choose based on the circuit's required RCD sensitivity."},{"question":"What is A9D01845's listed depth (72 mm) on this component line?","answer":"The A9D01845 has a depth of 72 mm, with height 110 mm and width 18 mm (2 × 9 mm pitches)."},{"question":"What compliance documentation does this brand provide for A9D01845 (RoHS, REACH, UL, IEC)?","answer":"The A9D01845 is certified to BS EN 61009-1, IEC 61009-1, and IEC 61009-2-2. It carries IP20/IP40 per IEC 60529. RoHS and REACH compliance documentation is standard for Schneider Electric Acti9 products; request specific declarations with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D01845","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D01845 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}