{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D02845","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D02845","canonicalUrl":"https://aoctrl.com/schneider/A9D02845","factsUrl":"https://aoctrl.com/api/mcp/products/A9D02845","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H RCBO, 1P+N, 45 A rated current at 50 °C, C-curve, 30 mA earth-leakage sensitivity, 10 kA breaking capacity, clip-on DIN rail mount.","salesMarkdown":"No need to rework the enclosure layout if you're swapping in a standard single-module width. The thermal-magnetic trip unit gives you the familiar bimetal-plus-solenoid response: no electronics to fail in high-ambient or dirty environments. The 45 A rating at 50 °C means this RCBO is already de-rated for a warm enclosure. The C-curve trips between 5 and 10 times In — so a 45 A C-curve holds through a 225 A to 450 A surge for short-duration motor starts or capacitor inrush, then clears a hard fault. The 30 mA residual sensitivity is the standard for socket-outlet and general-purpose circuits where direct contact protection is required per IEC 61009-1. It's integrated into the same housing — no separate RCD module needed, which saves a DIN position. Limitation class 3 means this device limits the let-through energy under fault conditions, which helps with downstream coordination and reduces stress on wiring and connected equipment. The 250 A surge current rating covers the magnetizing inrush of a small transformer or the charging current of a power-supply capacitor bank. Wire stripping length is 14 mm for the top connection, 13 mm for the bottom. The screw-clamp terminals are the traditional cage type — reliable, field-serviceable, and compatible with standard ferrule crimps. The device is padlockable with a 4 mm Ø padlock for lockout/tagout during maintenance. Standards compliance covers IEC 61009-1 and IEC 61009-2-2 — the international standard for RCBOs. The device is suitable for isolation, meaning it can be used as a disconnecting means for the outgoing circuit when padlocked off. For a final-distribution RCBO that sees occasional switching, that's a long service life.","metaTitle":"Schneider Electric A9D02845 Acti9 iC60 RCBO, 45A C-curve 30m","metaDescription":"Schneider Electric A9D02845 Acti9 iC60H RCBO, 1P+N, 45A rated current, C-curve, 30mA earth leakage, 10kA breaking capacity. Current lifecycle stage. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"110 mm","Standards":"IEC 61009-1 IEC 61009-2-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz","Device short name":"iC60H RCBO","Network frequency":"50 Hz","Poles description":"1P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom","[In] rated current":"45 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid Screw clamp terminal (bottom) 1...10 mm² flexible","IP degree of protection":"IP20 IP40 (modular enclosure)","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/hk/en/product/A9D02845/acti9-ic60h-rcbo-1p+ns-c-curve-45-a-30-ma-10000-a-240-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D02845/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9D02845?","answer":"The A9D02845 has a breaking capacity of 10,000 A Icn at 240 V AC, 50/60 Hz. That's the maximum fault current it can safely interrupt under standard test conditions."},{"question":"What is the earth-leakage sensitivity of this RCBO?","answer":"The earth-leakage sensitivity is 30 mA, which is the standard threshold for personal protection against direct contact in TN earthing systems."},{"question":"What is the rated current and curve for A9D02845?","answer":"It is rated at 45 A at 50 °C with a C-curve trip characteristic, suitable for motor-starting inrush and moderate inductive loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D02845","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D02845 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}