{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D04840","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D04840","canonicalUrl":"https://aoctrl.com/schneider/A9D04840","factsUrl":"https://aoctrl.com/api/mcp/products/A9D04840","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H RCBO, 1P + Ns, 40 A, 30 mA, curve B, 10 kA breaking capacity, clip-on DIN rail.","salesMarkdown":"It protects a single-phase outgoing circuit against overload, short-circuit, and earth leakage, with a rated current of 40 A at 50 °C and an earth-leakage sensitivity of 30 mA. Torque the top connection to 3.5 N·m and the bottom to 2 N·m. For a buyer sourcing this part, the paperwork is straightforward: the standards compliance covers most global markets, and the part carries the Schneider Electric brand with full traceability. ## Integration notes The module occupies 2 x 9 mm pitches (18 mm total width) on a DIN rail. Depth is 77.5 mm, height 110 mm. The toggle actuator provides ON/OFF local signalling and is padlockable with a 4 mm diameter padlock for lockout/tagout. The electrical durability is rated at 5,000 cycles, mechanical durability at 20,000 cycles — figures that reflect a typical panel-mounted distribution device rather than a high-cycling motor-switching role. The limitation class is 3, which limits let-through energy under fault conditions.","metaTitle":"Schneider Electric A9D04840 Acti9 iC60H RCBO, 40 A, 30 mA, C","metaDescription":"Schneider Electric A9D04840 Acti9 iC60H RCBO. 40 A rated current, 30 mA earth leakage, curve B, 10 kA breaking capacity. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"110 mm","Standards":"IEC 61009-1 IEC 61009-2-2","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz","Device short name":"iC60H RCBO","Network frequency":"50 Hz","Poles description":"1P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom","[In] rated current":"40 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible","IP degree of protection":"IP20 IP40 (modular enclosure)","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/hk/en/product/A9D04840/acti9-ic60h-rcbo-1p+ns-b-curve-40-a-30-ma-10000-a-240-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D04840/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the A9D04840?","answer":"Rated current 40 A at 50 °C, earth-leakage sensitivity 30 mA, curve B, breaking capacity 10 kA Icn at 240 V AC, thermal-magnetic trip, 1P + Ns poles."},{"question":"Where can I buy the A9D04840 and how is it quoted?","answer":"We source and quote this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does the A9D04840 comply with?","answer":"It complies with IEC 61009-1 and IEC 61009-2-2, the international standards for residual current operated circuit-breakers with integral overcurrent protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D04840","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D04840 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}