{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D06845","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D06845","canonicalUrl":"https://aoctrl.com/schneider/A9D06845","factsUrl":"https://aoctrl.com/api/mcp/products/A9D06845","rawCanonicalId":null},"summary":{"shortDescription":"Acti9 iC60H RCBO plug on neutral - 1P+Ns - 45A - C - 10000A - 100mA - type A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"72 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"110 mm","Standards":"BS EN 61009-1 IEC 61009-1 IEC 61009-2-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Plug-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"Fault indication ON/OFF indication","Mounting support":"Isobar A Isobar B","Neutral position":"Left","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IEC 61009-2-2","Device short name":"iC60H RCBO PoN","Network frequency":"50/60 Hz","Poles description":"1P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top 2 N.m bottom","[In] rated current":"45 A at 50 °C","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top connection 13 mm for bottom connection","Connections - terminals":"Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...10 mm² flexible Screw clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (bottom) 1...16 mm² rigid Plug-on neutral (upstream)","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Electrical insulation class":"Class II","Locking options description":"Padlock in on or off position","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 240 V AC 50/60 Hz conforming to IEC 61009-2-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$212.61","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D06845/acti9-ic60h-rcbo-plug-on-neutral-1p+ns-45a-c-10000a-100ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D06845/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D06845","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D06845 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}