{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D12840","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D12840","canonicalUrl":"https://aoctrl.com/schneider/A9D12840","factsUrl":"https://aoctrl.com/api/mcp/products/A9D12840","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 1P + Ns, 40 A, 10 kA Icn, 100 mA, Type C, clip-on DIN rail.","salesMarkdown":"It combines a 40 A thermal-magnetic trip (curve C) with integrated 100 mA earth-leakage protection, all in a 1P + Ns (switched neutral) format. Clip-on mounting to DIN rail, with a 77.5 mm depth that fits standard distribution boards. The 100 mA earth-leakage sensitivity is a common choice for general-purpose protection where 30 mA is not required; it reduces nuisance tripping on circuits with natural leakage. The 18 mm width occupies two 9 mm pitches on a DIN rail — standard for a 1P + N RCBO. Clip-on mounting with a grid distance of 45 mm. Screw-clamp terminals accept up to 25 mm² rigid on top and 16 mm² flexible on bottom; tightening torque is 3.5 N.m top, 2 N.m bottom.","metaTitle":"Schneider Electric A9D12840 Acti9 iC60 RCBO, 40 A, 10 kA, 10","metaDescription":"Schneider Electric A9D12840 Acti9 iC60 RCBO, 40 A rated, 10 kA breaking capacity, 100 mA earth-leakage sensitivity, Type C curve. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"110 mm","Standards":"BS EN 61009-1 IEC 61009-2-2 IEC 61009-1 AS/NZS 61009.1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Grid distance":"45 mm","Mounting mode":"Clip-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 230/240 V AC 50/60 Hz","Device short name":"iC60H RCBO","Network frequency":"50 Hz","Poles description":"1P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom","[In] rated current":"40 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 230/240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D12840/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60h-rcbo-1p+ns-40a-100ma-a-type-10000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D12840/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9D12840?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9D12840?","answer":"The breaking capacity is 10,000 A Icn at 230/240 V AC, 50/60 Hz. This is the maximum fault current the device can safely interrupt."},{"question":"What compliance documentation does Schneider provide for A9D12840?","answer":"The device is certified to BS EN 61009-1, IEC 61009-2-2, IEC 61009-1, and AS/NZS 61009.1. These standards cover the RCBO's performance and safety requirements. RoHS and REACH declarations are standard for the Acti9 range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D12840","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D12840 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}