{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D15832","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D15832","canonicalUrl":"https://aoctrl.com/schneider/A9D15832","factsUrl":"https://aoctrl.com/api/mcp/products/A9D15832","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H RCBO, A9D15832, 1P+N, 32 A, Curve C, 10 kA Icn at 240 V AC, 100 mA earth-leakage, IEC 61009-1.","salesMarkdown":"The A9D15832 is a Schneider Electric Acti9 iC60H RCBO — a residual current breaker with overcurrent protection in a 1P+N format, rated 32 A at 50 °C with a C trip curve and a 10 kA Icn breaking capacity at 240 V AC. The integrated earth-leakage protection is set at 100 mA sensitivity, making it suitable for TN earthing systems where both overcurrent and ground-fault protection are required in a single 18 mm wide module. In a typical domestic or light commercial distribution board fed by a transformer with a low-impedance path, that covers the majority of downstream faults. The 100 mA earth-leakage sensitivity is a deliberate choice — it is not a 30 mA personal-protection level. This RCBO is intended for equipment or circuit protection where a higher leakage threshold is acceptable (e.g., fixed industrial machinery, lighting circuits, or sub-distribution), not for socket-outlet circuits where 30 mA is standard for shock protection. The thermal-magnetic trip unit handles the overcurrent side; the integrated residual-current module handles the ground-fault side, all in one 18 mm wide, clip-on DIN-rail package. ## Integration and installation The toggle provides local ON/OFF indication, and the unit is padlockable with a 4 mm padlock for lockout/tagout.","metaTitle":"A9D15832 Acti9 iC60H RCBO, 32 A, 10 kA, Curve C, 1P+N","metaDescription":"Schneider Electric Acti9 iC60H RCBO A9D15832: 32 A, 10 kA Icn, Curve C, 1P+N, 100 mA earth-leakage, IEC 61009-1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"110 mm","Standards":"IEC 61009-2-2 IEC 61009-1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Grid distance":"45 mm","Mounting mode":"Clip-on","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz","Device short name":"iC60H RCBO","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom","[In] rated current":"32 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/A9D15832/ic60h-earth-leakage-circuit-breaker-1p-+-n-c-curve-32a-100-ma-240-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D15832/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9D15832?","answer":"The A9D15832 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of the A9D15832?","answer":"The breaking capacity is 10,000 A Icn at 240 V AC, 50/60 Hz, per IEC 61009-1."},{"question":"What earth-leakage sensitivity does the A9D15832 have?","answer":"The integrated earth-leakage protection is set at 100 mA sensitivity."},{"question":"What compliance standards does the A9D15832 meet?","answer":"It is certified to IEC 61009-2-2 and IEC 61009-1, covering both overcurrent and residual-current protection requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D15832","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D15832 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}