{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D15845","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D15845","canonicalUrl":"https://aoctrl.com/schneider/A9D15845","factsUrl":"https://aoctrl.com/api/mcp/products/A9D15845","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H RCBO, A9D15845, 1P+N, 45 A at 50 °C, 10 kA Icn, 100 mA earth leakage, Type C curve, thermal-magnetic trip, DIN-rail mount.","salesMarkdown":"It integrates earth-leakage detection and thermal-magnetic overcurrent trip into one DIN-rail unit, saving a pole position in the panel compared to separate MCB + RCCD. Earth-leakage sensitivity is 100 mA, integrated into the same body — no add-on module or external toroid. That sensitivity level is typical for circuits where 30 mA nuisance tripping is a concern (e.g., fixed equipment with natural leakage) but still provides personnel protection in some jurisdictions; verify local code for socket-outlet circuits. Clip-on mounting to DIN rail, 18 mm width (2 x 9 mm pitches), 110 mm height, 77.5 mm depth. Padlockable with a Ø 4 mm padlock for lockout/tagout. Screw-clamp terminals: top accepts 1–25 mm² rigid or 1–16 mm² flexible; bottom accepts 1–16 mm² rigid or 1–10 mm² flexible. Tightening torque 3.5 N.m top, 2 N.m bottom. Strip length 14 mm top, 13 mm bottom. Rated for TN earthing systems, 50 Hz network frequency. The toggle control gives ON/OFF indication and a contact position indicator confirms the state of the main contacts — useful during commissioning and fault-finding. Compliance: certified to IEC 61009-1 and IEC 61009-2-2, the harmonized standards for RCBOs. Tropicalisation class 2 indicates the device is treated for resistance to heat and humidity — 95 % RH at 55 °C. Suitability for isolation marked — it can be used as a disconnecting means. Electrical durability: 5000 cycles. Mechanical durability: 20000 cycles. Limitation class 3 — energy-limiting performance that reduces let-through energy under short-circuit conditions, protecting downstream equipment.","metaTitle":"Schneider Electric A9D15845 Acti9 iC60 RCBO, 45 A, 10 kA, 10","metaDescription":"Schneider Electric A9D15845 Acti9 iC60H RCBO, 45 A rated current, 10 kA breaking capacity, 100 mA earth leakage, Type C curve. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"110 mm","Standards":"IEC 61009-1 IEC 61009-2-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz","Device short name":"iC60H RCBO","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom","[In] rated current":"45 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/A9D15845/ic60h-earth-leakage-circuit-breaker-1p-+-n-c-curve-45-a-100-ma-240-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D15845/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9D15845 and what is the lead time?","answer":"The A9D15845 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time."},{"question":"What is the closest alternative to A9D15845 in the Acti9 range?","answer":"Within the Acti9 iC60 range, the closest sibling is the A9D15844 — identical except for the earth-leakage sensitivity (30 mA vs 100 mA on the A9D15845). Choose the 30 mA version where local codes require personnel protection on socket-outlet circuits; the 100 mA version suits fixed equipment circuits where 30 mA nuisance tripping is a concern."},{"question":"What compliance documentation does Schneider provide for A9D15845?","answer":"The A9D15845 is certified to IEC 61009-1 and IEC 61009-2-2, the international standards for RCBOs. It carries tropicalisation class 2 treatment for humidity resistance (95 % RH at 55 °C)."},{"question":"What is the depth of A9D15845?","answer":"The depth is 77.5 mm. Overall dimensions: 18 mm wide (2 x 9 mm pitches), 110 mm high, 77.5 mm deep — fits standard DIN-rail enclosures."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D15845","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D15845 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}