{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D16810","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D16810","canonicalUrl":"https://aoctrl.com/schneider/A9D16810","factsUrl":"https://aoctrl.com/api/mcp/products/A9D16810","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 IKQE RCBO, 1P+N, 10 A, 10 mA, C-curve, 10 kA, 230 V AC, DIN rail.","salesMarkdown":"The Schneider Electric A9D16810 is an Acti9 IKQE RCBO — a residual current breaker with overcurrent protection in a single 18 mm wide module (2 x 9 mm pitches). It combines thermal-magnetic overcurrent protection (C-curve, 10 A at 50 °C) with integrated earth-leakage protection set at 10 mA sensitivity, all in a 1P+N pole configuration. Rated breaking capacity is 10 000 A Icn at 230 V AC, 50/60 Hz, meeting Limitation Class 3 for high energy let-through reduction. Compliance is to BS EN 61009-1, the harmonised standard for RCBOs in the UK and EU. The part carries a white housing with toggle control and ON/OFF local indication, and is padlockable (Ø 4 mm padlock) for lockout/tagout. The 10 mA earth-leakage sensitivity is the key differentiator here — standard RCBOs are typically 30 mA. A 10 mA device is specified for circuits requiring enhanced protection against electric shock, such as socket outlets in bathrooms, laboratories, or other wet locations where the body resistance may be lower. At 18 mm wide (2 modules), the unit occupies a single DIN-rail position, leaving room for adjacent breakers or accessories in a crowded enclosure. Wire strip length is 13 mm.","metaTitle":"Schneider Electric A9D16810 IKQE RCBO, 10 A, 10 mA, C-curve,","metaDescription":"Schneider Electric A9D16810 IKQE RCBO, 10 A rated current, 10 mA earth leakage sensitivity, C-curve, 10 kA breaking capacity per BS EN 61009-1. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"82 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"118 mm","Standards":"BS EN 61009-1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"IKQE RCBO","Mounting mode":"Clip-on","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 230 V AC 50/60 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m top or bottom","[In] rated current":"10 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"10 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"10000 A at 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D16810/ikqe-earth-leakage-circuit-breaker-1p-+-n-c-curve-10-a-10-ma-230-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D16810/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9D16810?","answer":"The A9D16810 has a breaking capacity of 10 000 A Icn at 230 V AC, 50/60 Hz, meeting Limitation Class 3 for reduced let-through energy."},{"question":"What earth-leakage sensitivity does A9D16810 offer?","answer":"The A9D16810 is set at 10 mA earth-leakage sensitivity — a higher-sensitivity variant for circuits requiring enhanced shock protection."},{"question":"Where can I buy A9D16810?","answer":"The A9D16810 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D16810","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D16810 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}