{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D17213","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D17213","canonicalUrl":"https://aoctrl.com/schneider/A9D17213","factsUrl":"https://aoctrl.com/api/mcp/products/A9D17213","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, A9D17213, 2P, 13 A rated, 30 mA earth leakage, C-curve, 10 kA Icn, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9D17213 is an Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection, in a 2-pole (2P) form factor. It integrates both thermal-magnetic overcurrent tripping and 30 mA earth-leakage detection into a single 36 mm wide module that clips onto a DIN rail. The 13 A rating and 30 mA leakage sensitivity make this a go-to for final subcircuits in distribution boards: socket outlets, small appliance circuits, or lighting final circuits where personnel protection against indirect contact is required. Rated breaking capacity is 10 kA Icn at 220...240 V AC 50 Hz per EN/IEC 61009-2-1, with an ultimate breaking capacity (Icu) of 15 kA at the same voltage per EN/IEC 60947-2. The higher Icu figure gives headroom for coordination studies; if the upstream device limits the prospective fault current below 15 kA, this RCBO can handle the let-through without losing its integrity. Clip-on mounting to DIN rail — standard 35 mm symmetrical rail. Connection pitch is 9 mm between poles, which aligns with the busbar system for the Acti9 range. The toggle provides local signalling: ON, OFF, and fault-trip positions are clearly indicated. IP40 in a distribution enclosure, IP20 otherwise — so it's not rated for washdown environments; keep it inside a panel.","metaTitle":"Schneider Electric A9D17213 Acti9 iC60 RCBO, 13 A, 30 mA, C-","metaDescription":"Schneider Electric A9D17213 Acti9 iC60 RCBO, 13 A rated current, 30 mA earth leakage, C-curve, 2P, 10 kA breaking capacity. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"86 mm","Standards":"EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"250 A","Quality labels":"KEMA-KEUR VDE NF IMQ","Tropicalisation":"2","lifecycle_stage":"current","Connection pitch":"9 mm between poles","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iC60 RCBO","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"No conforming to IEC 60947-1","Contact position indicator":"No","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES Bottom: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9D17213/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-2p-13a-c-curve-10000a-15ka-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D17213/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9D17213 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of the A9D17213?","answer":"The A9D17213 has a rated breaking capacity (Icn) of 10 kA at 220...240 V AC 50 Hz per EN/IEC 61009-2-1, and an ultimate breaking capacity (Icu) of 15 kA at the same voltage per EN/IEC 60947-2."},{"question":"What compliance documentation does Schneider provide for the A9D17213?","answer":"The A9D17213 carries KEMA-KEUR, VDE, NF, and IMQ quality labels. It is certified to EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. RoHS and REACH compliance documentation is standard for the Acti9 range; request it with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D17213","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D17213 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}