{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D17216","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D17216","canonicalUrl":"https://aoctrl.com/schneider/A9D17216","factsUrl":"https://aoctrl.com/api/mcp/products/A9D17216","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 2P, 16 A, C-curve, 30 mA earth-leakage, 10 kA Icn, clip-on DIN rail.","salesMarkdown":"The A9D17216 is a 2-pole RCBO from the Acti9 iC60 family, combining a 16 A thermal-magnetic circuit breaker with integrated 30 mA earth-leakage protection in one 36 mm wide module. The C-curve (magnetic trip 5–10 × In) suits general-purpose loads like lighting, socket outlets, and small appliances where moderate inrush is expected. Rated breaking capacity is 10 000 A Icn at 230 V AC per EN/IEC 61009-2-1, with an ultimate breaking capacity (Icu) of 15 000 A at the same voltage per EN/IEC 60947-2. Rated for 10 000 electrical cycles and 20 000 mechanical cycles. IP40 in distribution enclosure (IP20 terminals). Tropicalisation class 2 means the part is treated for damp-heat environments up to 95 % RH at 55 °C. Terminal torque is 2 N·m; wire stripping length is 12 mm for top or bottom connection.","metaTitle":"A9D17216 Acti9 iC60 RCBO, 16 A, 30 mA, 10 kA, C-curve","metaDescription":"Schneider Electric A9D17216 Acti9 iC60 RCBO. 16 A rated, 30 mA earth-leakage, 10 kA breaking capacity, C-curve. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"86 mm","Standards":"EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"250 A","Quality labels":"VDE IMQ NF KEMA-KEUR","Tropicalisation":"2","lifecycle_stage":"current","Connection pitch":"9 mm between poles","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iC60 RCBO","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"16 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"No conforming to IEC 60947-1","Contact position indicator":"No","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES Bottom: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9D17216/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-2p-16a-c-curve-10000a-15ka-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D17216/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9D17216 and get current pricing?","answer":"The A9D17216 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are listed here."},{"question":"What compliance documentation does Schneider Electric provide for A9D17216?","answer":"The part carries quality labels VDE, IMQ, NF, and KEMA-KEUR, and conforms to EN/IEC 60947-2 and EN/IEC 61009-2-1. RoHS and REACH compliance documentation is standard for Acti9 products; specific certificates are available from Schneider Electric upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D17216","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D17216 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}