{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D17320","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D17320","canonicalUrl":"https://aoctrl.com/schneider/A9D17320","factsUrl":"https://aoctrl.com/api/mcp/products/A9D17320","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 3-pole, 20 A, 30 mA earth-leakage, curve C, 10 kA Icn, DIN rail clip-on.","salesMarkdown":"It integrates a thermal-magnetic trip unit for overload and short-circuit protection with a 30 mA residual-current element, all in a single 54 mm wide module that clips onto a DIN rail. The 10 kA Icn breaking capacity at 220–240 V AC (15 kA Icu per EN/IEC 60947-2) means it safely clears a fault up to that level without welding its contacts — enough for most commercial and light industrial sub-distribution boards. The 30 mA earth-leakage sensitivity provides personal protection against direct contact with live parts, consistent with the requirements of IEC 60364 for socket-outlet circuits and final subcircuits in wet or outdoor locations. Clip-on mounting to a standard DIN rail, 6 modules wide at 9 mm pitch (54 mm total). IP40 in a distribution enclosure (IP20 for the terminal area) makes it suitable for clean, dry indoor panels. The white housing and toggle control give clear visual indication of ON, OFF, and fault-trip states.","metaTitle":"Schneider Electric A9D17320 Acti9 iC60 RCBO, 20 A, 30 mA, 3P","metaDescription":"Schneider Electric A9D17320 Acti9 iC60 RCBO. 20 A rated current, 30 mA earth-leakage sensitivity, 3-pole, curve C. 10 kA Icn breaking capacity. DIN rail mount. Sourced to order aga","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"86 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"250 A","Quality labels":"KEMA-KEUR VDE IMQ NF","Tropicalisation":"2","lifecycle_stage":"current","Connection pitch":"9 mm between poles","Limitation class":"1 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iC60 RCBO","Network frequency":"50 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"20 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"No conforming to IEC 60947-1","Contact position indicator":"No","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES Bottom: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9D17320/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-3p-20a-c-curve-10000a-15ka-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D17320/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9D17320?","answer":"10 kA Icn at 220–240 V AC 50 Hz per EN/IEC 61009-2-1, and 15 kA Icu at the same voltage per EN/IEC 60947-2."},{"question":"What compliance documentation does the A9D17320 carry?","answer":"It is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1, with quality marks from KEMA-KEUR, VDE, IMQ, and NF."},{"question":"Where can I buy the A9D17320 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D17320","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D17320 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}