{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D17845","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D17845","canonicalUrl":"https://aoctrl.com/schneider/A9D17845","factsUrl":"https://aoctrl.com/api/mcp/products/A9D17845","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 IKQE RCBO, residual current breaker with overcurrent protection, 1P+N, 45 A, 30 mA, C-curve, 10 kA, clip-on DIN rail.","salesMarkdown":"It combines a 45 A thermal-magnetic MCB (C-curve) with a 30 mA earth-leakage trip, all in a 1P+N format for TN earthing systems on 50 Hz AC networks. The 45 A rated current at 50 °C is the continuous load the RCBO can carry without tripping on thermal overload. The 30 mA earth-leakage sensitivity provides additional protection against electric shock for final circuits — standard for socket-outlet circuits and general-purpose power in most commercial installations. The integrated earth-leakage block means one device does both jobs, saving a DIN-rail position compared to a separate MCB + RCCB pair. Limitation class 3 means the RCBO limits let-through energy (I²t) well, reducing stress on downstream equipment during a short-circuit. The 5000-cycle electrical durability and 20,000-cycle mechanical durability are typical for a distribution RCBO — not a motor-switching duty cycle, but fine for occasional manual operation and fault clearing. IP20 rated — protected against solid objects over 12 mm, no water ingress protection. This is a panel-inside device; it lives behind an enclosure door. ## Integration notes Occupies 2 x 18 mm module pitches. Strip length 13 mm. Padlockable with a Ø 4 mm padlock for lockout/tagout. The contact position indicator shows ON/OFF status visibly on the toggle. Rated for TN earthing systems. Device location in the system is marked as outgoer — it's a final-circuit protective device, not a main switch or incomer.","metaTitle":"Schneider Electric A9D17845 Acti9 IKQE RCBO, 45A, 30mA, C-Cu","metaDescription":"Schneider Electric A9D17845 Acti9 IKQE RCBO. 45A rated current, 30mA earth leakage, C-curve, 10kA breaking capacity. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"82 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"118 mm","Standards":"BS EN 61009-1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"IKQE RCBO","Mounting mode":"Clip-on","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 230 V AC 50/60 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m top or bottom","[In] rated current":"45 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"10000 A at 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D17845/ikqe-earth-leakage-circuit-breaker-1p-+-n-c-curve-45-a-30-ma-230-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D17845/alternatives.json"},"ai":{"faq":[{"question":"What is A9D17845's listed depth (82 mm) on this component line?","answer":"The depth is 82 mm. Combined with the 118 mm height and 18 mm width (2 module pitches), it fits standard distribution board cutouts for Acti9 devices."},{"question":"What is A9D17845's listed range (Acti9) on this component line?","answer":"It belongs to the Schneider Electric Acti9 range, specifically the IKQE series of RCBOs (residual current breakers with overcurrent protection). Acti9 is the modular DIN-rail platform for final-distribution protection."},{"question":"What compliance documentation does this brand provide for A9D17845 (RoHS, REACH, UL, IEC)?","answer":"The A9D17845 is certified to BS EN 61009-1, the harmonized European standard for RCBOs. It carries CE marking for the European market. RoHS and REACH compliance is standard for Schneider Acti9 products, though specific declarations are issued per batch."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D17845","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D17845 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}