{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D32713","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D32713","canonicalUrl":"https://aoctrl.com/schneider/A9D32713","factsUrl":"https://aoctrl.com/api/mcp/products/A9D32713","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi RCBO, A9D32713, 3P+N, 13 A rated, C-curve, 30 mA earth-leakage, 6 kA breaking capacity, DIN rail clip-on.","salesMarkdown":"It protects a 13 A final circuit against overload, short-circuit (C-curve, magnetic trip 5–10 x In), and earth leakage at 30 mA sensitivity. The thermal-magnetic trip unit and integrated earth-leakage detection mean one device covers both fault types, saving a DIN-rail slot versus separate MCB + RCCB. Breaking capacity is 6000 A Icn at 380–415 V AC, 50/60 Hz, per EN/IEC 61009-2-1. Rated at 13 A, this RCBO sits in a 3P+N configuration (three protected poles plus switched neutral, neutral left). The 30 mA earth-leakage threshold provides additional shock protection for socket-outlet circuits or wet-area final circuits. Limitation class 3 (energy-limiting) means it restricts let-through energy during a fault, aiding downstream device coordination. Clip-on mounting to DIN rail (35 mm per EN 60715). The module occupies 10 x 9 mm pitches — 90 mm width total — with an 18 mm pitch between phases and 9 mm between phase and neutral. Depth is 78.5 mm, height 91 mm. Tunnel-type terminals accept 0.75–16 mm² rigid or 0.33–10 mm² flexible (with or without ferrule); tighten to 2 N·m. IP20 on the body, IP40 inside a modular enclosure.","metaTitle":"Schneider Electric A9D32713 Acti9 DPN Vigi RCBO, 13 A, 30 mA","metaDescription":"Schneider Electric A9D32713 Acti9 DPN Vigi RCBO, 13 A rated, 30 mA earth leakage, C-curve, 6 kA breaking capacity, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"90 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"10","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases 9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 380...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"90 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 0.75...16 mm² rigid Tunnel type terminal top or bottom 0.33...10 mm² flexible Tunnel type terminal top or bottom 0.33...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device Sealable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"380...415 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 6000 A at 380...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-30...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 380...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D32713/acti9-dpn-n-vigi-rcbo-3p+n-13a-c-curve-6000a-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D32713/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9D32713?","answer":"6000 A Icn at 380–415 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1."},{"question":"What compliance standards does A9D32713 meet?","answer":"It complies with EN/IEC 61009-2-1 (RCBO standard), IEC 60068-1 (tropicalisation class 2), and overvoltage category III per IEC 60364. Pollution degree 3."},{"question":"Where can I buy A9D32713 and how is it quoted?","answer":"This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D32713","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D32713 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}