{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D35620","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D35620","canonicalUrl":"https://aoctrl.com/schneider/A9D35620","factsUrl":"https://aoctrl.com/api/mcp/products/A9D35620","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, A9D35620, 1P+N, 20 A rated, C-curve, 30 mA earth leakage, 4.5 kA breaking capacity, clip-on DIN rail mount.","salesMarkdown":"It integrates a thermal-magnetic trip unit for overload and short-circuit protection with a 30 mA residual-current detection element, all in a single clip-on DIN-rail housing. Rated 20 A (In) with a breaking capacity of 4500 A Icn at 230...240 V AC 50 Hz, certified to EN/IEC 61009-2-1. The 30 mA earth-leakage sensitivity provides additional protection against indirect contact and fire risk from sustained earth faults. The thermal-magnetic trip technology means the bimetal handles sustained overloads (time-delayed) while the solenoid trips instantaneously on short-circuit currents above the magnetic threshold. The C-curve (5...10 × In) means the instantaneous magnetic trip operates between 100 A and 200 A for this 20 A unit. Clip-on mounting to DIN rail (EN 60715) — no tools needed for installation, consistent with the Acti9 modular system. The 36 mm width (4 × 9 mm pitches) houses both the phase and switched neutral poles in one module, saving one DIN space compared to a separate MCB + RCCB pair. Terminals accept 1...16 mm² solid or 1...10 mm² flexible (with or without ferrule); wire strip length is 15 mm and tightening torque is 2 N·m. IP20 on the front (finger-safe), IP40 inside the modular enclosure — standard for distribution boards. Designed and certified to EN/IEC 61009-2-1 (the RCBO product standard). Overvoltage category III per IEC 60364, pollution degree 3 — suitable for fixed installations inside distribution boards where transient overvoltages are controlled by upstream SPDs.","metaTitle":"Schneider Electric A9D35620 Acti9 iDPN Vigi RCBO, 20A C-curv","metaDescription":"Schneider Electric A9D35620 Acti9 iDPN Vigi RCBO, 20A rated, C-curve, 30mA earth leakage, 4.5kA breaking capacity. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"4500 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPNa Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"20 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"4500 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$237.38","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9D35620/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpna-vigi-1p+n-20a-c-curve-4500a-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D35620/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9D35620?","answer":"The breaking capacity is 4500 A Icn at 230...240 V AC 50 Hz, certified to EN/IEC 61009-2-1. This is the standard domestic/commercial fault-interruption rating for final circuits."},{"question":"Where can I buy A9D35620 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quotation — submit an RFQ for a firm commercial offer."},{"question":"What does the C-curve on A9D35620 mean?","answer":"The C-curve means the magnetic trip operates at 5 to 10 times the rated current (100 to 200 A for this 20 A unit). It is designed for general-purpose circuits with moderate inrush — lighting, socket outlets, small motors — without nuisance tripping."},{"question":"What is the earth-leakage sensitivity of A9D35620?","answer":"The integrated residual-current device trips at 30 mA sensitivity, providing additional protection against indirect contact and earth-fault fire risk in final circuits."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D35620","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D35620 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}