{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D37232","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D37232","canonicalUrl":"https://aoctrl.com/schneider/A9D37232","factsUrl":"https://aoctrl.com/api/mcp/products/A9D37232","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, A9D37232, 2P, 32 A, 30 mA earth-leakage, B-curve, 10 kA Icn, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9D37232 is an Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection in one 36 mm-wide, 2-pole module. It carries a 32 A rated current (In) with a B-curve magnetic trip (3 to 5 × In), and integrated 30 mA earth-leakage protection. The unit is rated for 10 kA Icn at 220–240 V AC, 50 Hz per EN/IEC 61009-2-1, with a 15 kA Icu per EN/IEC 60947-2. This is a thermal-magnetic trip device, so it responds to both overload (thermal) and short-circuit (magnetic) events, plus residual ground-fault currents down to 30 mA. Clip-on mounting to DIN rail, 4 pitches at 9 mm between poles — so it occupies 36 mm of rail width. The tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable, with a 2 N·m tightening torque and 12 mm strip length. IP40 in a distribution enclosure, IP20 bare. The toggle provides local signalling for ON, OFF, and fault-trip status. Intended as an outgoer device in a final distribution circuit.","metaTitle":"Schneider Electric A9D37232 Acti9 iC60 RCBO, 32 A, 30 mA, Ty","metaDescription":"Schneider Electric A9D37232 Acti9 iC60 RCBO, 32 A rated, 30 mA earth leakage, 10 kA breaking capacity. Active production. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"86 mm","Standards":"EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"250 A","Quality labels":"NF IMQ VDE KEMA-KEUR","Tropicalisation":"2","lifecycle_stage":"current","Connection pitch":"9 mm between poles","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iC60 RCBO","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"No conforming to IEC 60947-1","Contact position indicator":"No","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES Bottom: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9D37232/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-2p-32a-b-curve-10000a-15ka-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D37232/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9D37232?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels — no stock figures or price lists are published here."},{"question":"What compliance documentation does this brand provide for A9D37232?","answer":"The part carries EN/IEC 60947-2 and EN/IEC 61009-2-1 standards compliance, plus quality labels NF, IMQ, VDE, and KEMA-KEUR. Overvoltage category III per IEC 60364. Documentation for RoHS, REACH, and UL should be available from the manufacturer's support portal."},{"question":"What is A9D37232's listed depth (78 mm) on this component line?","answer":"The depth is 78 mm, with a height of 86 mm and width of 36 mm (4 × 9 mm pitches). This is a standard 2-module DIN-rail footprint."},{"question":"What is A9D37232's listed range (Acti9) on this component line?","answer":"It belongs to the Schneider Electric Acti9 range, specifically the iC60 RCBO series — a family of combined overcurrent and residual-current protection devices for final distribution circuits."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D37232","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D37232 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}