{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D37625","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D37625","canonicalUrl":"https://aoctrl.com/schneider/A9D37625","factsUrl":"https://aoctrl.com/api/mcp/products/A9D37625","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi, RCBO, 1P+N, 25 A, C-curve, 30 mA earth-leakage, 10 kA breaking capacity, DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9D37625 is an Acti9 iDPN Vigi residual-current circuit breaker with overcurrent protection (RCBO), combining a 25 A thermal-magnetic trip (C-curve, 5–10× In magnetic threshold) with integrated 30 mA earth-leakage protection in a single 1P+N module. The 25 A rated current (In) governs the continuous load the RCBO can carry without tripping on thermal overload — sized for a 25 A feeder or final circuit. The 30 mA earth-leakage sensitivity provides personal protection against direct contact (30 mA is the standard threshold for shock protection per IEC 60364). The 10 kA Icn breaking capacity at 230–240 V AC 50 Hz tells you this RCBO can safely interrupt a fault current up to 10 kA without welding contacts or failing — that's the standard domestic/commercial rating for most European distribution boards; if your prospective fault current exceeds 10 kA, you need a current-limiting upstream device or a higher-rated breaker. This is an outgoer device — it protects the final circuit, not the incoming supply. Clip it onto a DIN rail (EN 60715) inside an Acti9 enclosure or any standard modular distribution board. The 9 mm pitch between phase and neutral matches the Acti9 busbar system, so you can feed it from a common busbar without extra wiring.","metaTitle":"Schneider Electric A9D37625 Acti9 iDPN Vigi RCBO, 25A C-curv","metaDescription":"Schneider Electric A9D37625 Acti9 iDPN Vigi RCBO, 25A rated, C-curve, 30 mA earth-leakage, 10 kA breaking capacity. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"10000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN H Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"25 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$59.50","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9D37625/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-h-vigi-1p+n-25a-c-curve-10000a-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D37625/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9D37625?","answer":"The breaking capacity is 10,000 A Icn at 230–240 V AC 50 Hz, conforming to EN/IEC 61009-2-1."},{"question":"What earth-leakage sensitivity does A9D37625 have?","answer":"30 mA, integrated into the device — no external RCCB needed."},{"question":"Where can I buy A9D37625?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does A9D37625 comply with?","answer":"It complies with EN/IEC 61009-2-1 and EN/IEC 61009-1, covering RCBO performance and safety requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D37625","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D37625 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}