{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D37806","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D37806","canonicalUrl":"https://aoctrl.com/schneider/A9D37806","factsUrl":"https://aoctrl.com/api/mcp/products/A9D37806","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 IKQE RCBO, 1P+N, 6 A, 30 mA, curve B, 10 kA breaking capacity, DIN rail mount.","salesMarkdown":"## What this RCBO does in the panel It protects a single-phase outgoing circuit (1P+N, neutral left) against overload, short-circuit, and earth leakage in one unit, saving a DIN-rail position versus separate MCB and RCCB. Rated at 6 A with a type B tripping curve, it is sized for lighting, socket outlets, or small control circuits where the inrush is modest and nuisance tripping on cable charging is not a concern. The 30 mA earth-leakage sensitivity provides additional shock protection for personnel in TN earthing systems. The limitation class 3 rating means it lets through less fault energy than a standard breaker, helping downstream selectivity. Tunnel-type terminals accept 1 to 16 mm² rigid cable or 1 to 10 mm² flexible (with or without ferrule); strip length is 13 mm. IP20 rated — suitable for installation inside a distribution board or enclosure. The toggle control provides local ON/OFF indication, and the contact position indicator confirms the state of the main contacts. A padlock with Ø 4 mm shackle can lock the toggle in the OFF position for isolation during maintenance. Sourced through the authorised distribution channel. The part carries full factory traceability and warranty through the franchise line.","metaTitle":"Schneider Electric A9D37806 IKQE RCBO, 6 A, 30 mA, Curve B,","metaDescription":"Schneider Electric A9D37806 Acti9 IKQE RCBO, 1P+N, 6 A rated current, 30 mA earth leakage, curve B, 10 kA breaking capacity. Active production, sourced to order. BS EN 61009-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"82 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"118 mm","Standards":"BS EN 61009-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"IKQE RCBO","Mounting mode":"Clip-on","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 230 V AC 50/60 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m top or bottom","[In] rated current":"6 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"10000 A at 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D37806/ikqe-earth-leakage-circuit-breaker-1p-+-n-b-curve-6-a-30-ma-230-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D37806/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9D37806?","answer":"The breaking capacity is 10,000 A Icn at 230 V AC, 50/60 Hz. This is the rated short-circuit capacity per BS EN 61009-1."},{"question":"What is the earth leakage sensitivity of this RCBO?","answer":"The earth-leakage sensitivity is 30 mA, providing personnel protection against indirect contact and supplementary protection against direct contact."},{"question":"Where can I buy A9D37806 and how is it quoted?","answer":"The A9D37806 is sourced through the authorised distribution channel. Submit an RFQ for current pricing and availability — quotes are confirmed at time of request with full factory traceability and warranty."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D37806","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D37806 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}