{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D37810","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D37810","canonicalUrl":"https://aoctrl.com/schneider/A9D37810","factsUrl":"https://aoctrl.com/api/mcp/products/A9D37810","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 IKQE RCBO, 1P+N, 10 A rated current, 30 mA earth-leakage sensitivity, curve B, 10 kA breaking capacity at 230 V AC, BS EN 61009-1.","salesMarkdown":"It carries a 10 A rated current (at 50 °C) and a 30 mA earth-leakage sensitivity, with a curve B trip characteristic and a 10 kA breaking capacity at 230 V AC. The thermal-magnetic trip unit handles both overload and short-circuit protection, while the integrated earth-leakage detection covers ground faults. The 10 A rated current sets the continuous load capacity — this RCBO is sized for lighting or general-purpose socket circuits drawing up to 10 A. The 30 mA earth-leakage sensitivity provides personal protection against indirect contact and is the standard threshold for socket-outlet circuits in many residential and commercial installations. The toggle control provides ON/OFF indication, and the device can be padlocked with a 4 mm padlock. It is designed as an outgoer in the distribution board. The A9D37810 is certified to BS EN 61009-1, the harmonized standard for RCBOs covering both overcurrent and residual current protection. The IP20 protection degree confirms it is touch-proof but not water-resistant — install inside a suitable enclosure. The tropicalisation class 2 indicates it can withstand higher humidity and temperature cycling typical of tropical climates.","metaTitle":"Schneider Electric A9D37810 IKQE RCBO, 10 A, 30 mA, Curve B,","metaDescription":"Schneider Electric A9D37810 Acti9 IKQE RCBO, 1P+N, 10 A rated current, 30 mA earth-leakage sensitivity, curve B, 10 kA breaking capacity. BS EN 61009-1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"82 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"118 mm","Standards":"BS EN 61009-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"IKQE RCBO","Mounting mode":"Clip-on","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 230 V AC 50/60 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m top or bottom","[In] rated current":"10 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"10000 A at 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D37810/ikqe-earth-leakage-circuit-breaker-1p-+-n-b-curve-10-a-30-ma-230-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D37810/alternatives.json"},"ai":{"faq":[{"question":"What is the A9D37810 used for?","answer":"It is a combined residual current breaker with overcurrent protection (RCBO) for distribution circuits, rated 10 A with 30 mA earth-leakage sensitivity, curve B, and 10 kA breaking capacity at 230 V AC — typically used for lighting or socket-outlet circuits in TN earthing systems."},{"question":"Where can I buy the A9D37810?","answer":"The A9D37810 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the depth of the A9D37810?","answer":"The depth is 82 mm, with a height of 118 mm and a width of 18 mm (2 x 9 mm pitches)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D37810","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D37810 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}