{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D37816","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D37816","canonicalUrl":"https://aoctrl.com/schneider/A9D37816","factsUrl":"https://aoctrl.com/api/mcp/products/A9D37816","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 IKQE RCBO, 1P+N, 16 A rated, 30 mA earth leakage, B curve, 10 kA breaking capacity, clip-on DIN rail mount.","salesMarkdown":"Rated 16 A at 50 °C with 30 mA earth-leakage sensitivity and a B tripping curve, it breaks 10 kA (Icn) at 230 V AC. Clip-on mounting to a standard DIN rail (35 mm) — no tools needed for installation. Neutral is on the left, line on the right, which matches the busbar orientation in most Acti9 boards. Built to BS EN 61009-1, the harmonized standard for RCBOs in the UK and EU. The B-curve characteristic trips between 3 and 5 times rated current (48–80 A) for short-circuit protection, paired with the 30 mA residual-current element for shock protection in TN earthing systems. IP20 rated for clean, dry indoor enclosures only.","metaTitle":"Schneider Electric A9D37816 IKQE RCBO, 16A, 30mA, B Curve, 1","metaDescription":"Schneider Electric A9D37816 Acti9 IKQE RCBO, 1P+N, 16A rated current, 30mA earth leakage, B curve, 10kA breaking capacity. Current production. Sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"82 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"118 mm","Standards":"BS EN 61009-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"IKQE RCBO","Mounting mode":"Clip-on","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 230 V AC 50/60 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m top or bottom","[In] rated current":"16 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"10000 A at 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D37816/ikqe-earth-leakage-circuit-breaker-1p-+-n-b-curve-16-a-30-ma-230-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D37816/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9D37816?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock levels are confirmed at quote time."},{"question":"What is A9D37816's breaking capacity?","answer":"10,000 A Icn at 230 V AC, 50/60 Hz. That is the maximum fault current the RCBO can safely interrupt under standard conditions."},{"question":"What is the closest alternative to A9D37816 in the Acti9 range?","answer":"Within the same IKQE family, the main variant is the C-curve version (e.g., A9D37817). The B curve on this unit trips faster on moderate overloads — preferred for circuits with resistive loads or long cable runs where inrush is low. The footprint, breaking capacity, and earth-leakage sensitivity are identical."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D37816","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D37816 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}