{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D37825","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D37825","canonicalUrl":"https://aoctrl.com/schneider/A9D37825","factsUrl":"https://aoctrl.com/api/mcp/products/A9D37825","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 IKQE RCBO, 1P+N, 25 A rated current, 30 mA earth leakage sensitivity, curve B, 10 kA breaking capacity at 230 V AC, BS EN 61009-1.","salesMarkdown":"It protects a 1P+N circuit at 25 A rated current with 30 mA earth leakage sensitivity, curve B trip characteristic, and a 10 kA breaking capacity at 230 V AC. This is the part you spec when you need both overcurrent and earth leakage protection in one DIN-rail unit, saving a module width over separate MCB + RCCB. The 25 A rated current at 50 °C is the continuous load it can carry without tripping — size your downstream cable and load to stay under that. The 30 mA earth leakage sensitivity is standard for personnel protection (shock hazard) per BS EN 61009-1; it will trip on any ground fault above that threshold. Neutral on the left. IP20 rated — fine inside an enclosure, not for wet locations. The toggle gives local ON/OFF indication and the unit is padlockable with a 4 mm hasp for lockout/tagout. Position it as an outgoer feeding a final subcircuit.","metaTitle":"Schneider Electric A9D37825 IKQE RCBO, 25 A, 30 mA, Curve B,","metaDescription":"Schneider Electric A9D37825 Acti9 IKQE RCBO, 1P+N, 25 A rated current, 30 mA earth leakage, curve B, 10 kA breaking capacity, BS EN 61009-1. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"82 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"118 mm","Standards":"BS EN 61009-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"IKQE RCBO","Mounting mode":"Clip-on","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 230 V AC 50/60 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m top or bottom","[In] rated current":"25 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"10000 A at 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D37825/ikqe-earth-leakage-circuit-breaker-1p-+-n-b-curve-25-a-30-ma-230-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D37825/alternatives.json"},"ai":{"faq":[{"question":"What is A9D37825's rated current and earth leakage sensitivity?","answer":"It is rated 25 A at 50 °C with 30 mA earth leakage sensitivity, curve B trip characteristic, and 10 kA breaking capacity at 230 V AC."},{"question":"What standard does A9D37825 comply with?","answer":"It complies with BS EN 61009-1, the harmonized standard for RCBOs combining overcurrent and residual current protection."},{"question":"Where can I buy A9D37825 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D37825","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D37825 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}