{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D40606","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D40606","canonicalUrl":"https://aoctrl.com/schneider/A9D40606","factsUrl":"https://aoctrl.com/api/mcp/products/A9D40606","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 ISPN Vigi RCBO, 6 A rated, C-curve, 10 mA earth leakage, 6 kA breaking capacity, 1P+N, DIN rail mount.","salesMarkdown":"It protects a single-phase final subcircuit against both overload/short-circuit (thermal-magnetic trip, C-curve) and earth leakage (10 mA sensitivity). Rated 6 A at 30 °C, it's sized for lighting, small appliance, or control transformer circuits where personnel protection from ground faults is required. The 10 mA earth leakage sensitivity is tighter than the standard 30 mA used for socket-outlet protection; it's meant for wet locations, medical equipment, or any circuit where a lower fault threshold is specified by code. Breaking capacity is 6 kA Icn at 230/240 V AC, 50 Hz — adequate for most residential and light commercial distribution boards, but check the prospective short-circuit current at the point of installation; if it exceeds 6 kA, you need a current-limiting upstream device or a higher-rated breaker. ## DIN rail integration and wiring Clip-on mounting to standard DIN rail, 2 module pitches (18 mm each). Neutral on the left, phase on the right. Tunnel-type terminals: upstream accepts 1–16 mm² rigid or flexible, downstream 1–10 mm². Strip lengths are 13 mm upstream, 11 mm downstream. The white housing carries a toggle switch with ON/OFF indication and a contact position indicator, plus locking facilities for lockout/tagout. IP20 rated — fine inside an enclosure, not for wet washdown. Listed as current production (active lifecycle stage). The Acti9 range is Schneider's standard residential and light commercial platform, widely specified in Australia, New Zealand, and parts of Asia and the Middle East. Complies with AS/NZS 61009.1 and IEC 61009-2-2. Rated insulation voltage 400 V AC. Electrical endurance 10,000 cycles, mechanical 20,000 cycles.","metaTitle":"Schneider Electric A9D40606 Acti9 RCBO, 6A C-Curve, 10mA, 1P","metaDescription":"Schneider Electric A9D40606 Acti9 ISPN Vigi RCBO. 6A rated, C-curve, 10mA earth leakage, 6kA breaking capacity. DIN rail mount, 1P+N. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"93 mm","Standards":"AS/NZS 61009.1 IEC 61009-2-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"ISPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"6000 A Icn at 230/240 V AC 50 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m upstream 2 N.m downstream","[In] rated current":"6 A at 30 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"11 mm for downstream connection 13 mm for upstream connection","Connections - terminals":"Tunnel type terminal (upstream) 1...16 mm² rigid Tunnel type terminal (downstream) 1...10 mm² rigid Tunnel type terminal (upstream) 1...16 mm² flexible Tunnel type terminal (downstream) 1...10 mm² flexible","IP degree of protection":"IP20","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"10 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50 Hz","Ambient air temperature for storage":"-25...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-25...55 °C","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 500 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/A9D40606/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ispn-vigi-1p-+-n-6a-10ma-a-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D40606/alternatives.json"},"ai":{"faq":[{"question":"What is the A9D40606 used for?","answer":"It's a 1P+N RCBO combining overcurrent protection (6 A, C-curve) and earth leakage protection (10 mA) in one DIN-rail module, typically used for final subcircuits in distribution boards where both fault types must be covered."},{"question":"Where can I buy the A9D40606?","answer":"It is sourced and quoted to order against an RFQ through independent distribution channels. Contact us for a current price and availability quote."},{"question":"What standards does the A9D40606 comply with?","answer":"It complies with AS/NZS 61009.1 and IEC 61009-2-2, the standards for residual current operated circuit breakers with integral overcurrent protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D40606","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D40606 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}