{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D43620","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D43620","canonicalUrl":"https://aoctrl.com/schneider/A9D43620","factsUrl":"https://aoctrl.com/api/mcp/products/A9D43620","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 20 A, C-curve, 300 mA earth leakage, 6 kA breaking capacity, DIN-rail mount.","salesMarkdown":"The A9D43620 is a Schneider Electric Acti9 iDPN Vigi residual-current circuit breaker with overcurrent protection (RCBO) — one module wide, 1P+N, rated 20 A with a C-curve magnetic trip (5...10 x In) and integrated 300 mA earth-leakage protection. The 6 kA breaking capacity at 230...240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1, is the standard domestic fault-clearing level across most of Europe; the C-curve means it handles moderate inrush from loads like small motors or lighting banks without nuisance tripping. The 20 A rated current (In) and C-curve suit general-purpose final circuits feeding socket outlets, lighting, or small appliances — not heavy motor or welding loads. The 300 mA earth-leakage sensitivity is a protection level for fire prevention or equipment protection, not personal shock protection (that requires 30 mA or lower). The IP20 (finger-safe) and IP40 (enclosure) ratings mean it is protected against solid objects but not moisture — standard for indoor distribution boards. Terminals accept 1...16 mm² rigid or 1...10 mm² flexible (with or without ferrule); strip 15 mm, tighten to 2 N.m. The 9 mm connection pitch between phase and neutral is standard for the Acti9 range, so it mates directly with busbars and adjacent devices without adaptors.","metaTitle":"A9D43620 Acti9 iDPN Vigi 20A C-curve RCBO, 6kA","metaDescription":"A9D43620 Acti9 iDPN Vigi RCBO, 20A C-curve, 300mA earth leakage, 6kA breaking capacity. Active production. Sourced to order. Quoted against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN N Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"20 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/uk/en/product/A9D43620/residual-current-breaker-with-overcur-prot-rcbo-acti9-idpn-n-vigi-1p+n-20a-c-curve-6000a-asi-type-300ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D43620/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9D43620 and what is the lead time?","answer":"The A9D43620 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to A9D43620 in this component family?","answer":"No official pin-compatible alternative is recorded for the A9D43620 within the Acti9 iDPN Vigi range — it is the current standard part for this specification."},{"question":"What is A9D43620's listed depth (73 mm) on this component line?","answer":"The A9D43620 has a depth of 73 mm."},{"question":"What is A9D43620's listed range (Acti9) on this component line?","answer":"The A9D43620 belongs to the Schneider Electric Acti9 range."},{"question":"What compliance documentation does this brand provide for A9D43620 (RoHS, REACH, UL, IEC)?","answer":"The A9D43620 is certified to EN/IEC 61009-2-1 and carries a pollution degree 3 rating conforming to IEC 60364. The evidence does not list RoHS, REACH, or UL documentation specifically for this order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D43620","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D43620 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}