{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D44616","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D44616","canonicalUrl":"https://aoctrl.com/schneider/A9D44616","factsUrl":"https://aoctrl.com/api/mcp/products/A9D44616","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 16 A, C-curve, 30 mA earth-leakage sensitivity, 4.5 kA breaking capacity, clip-on DIN rail mount.","salesMarkdown":"The A9D44616: The C-curve means magnetic tripping happens between 5 and 10 times the rated current (80 to 160 A), which suits mixed resistive and moderate-inductive loads like lighting circuits, small motorised valves, and general socket outlets. The 300 mA earth-leakage threshold is a common choice for distribution sub-circuits where personnel protection (30 mA) is not required — think fixed equipment, water heaters, or industrial socket banks fed through an upstream 30 mA RCD. Breaking capacity is 4.5 kA at 230…240 V AC, 50 Hz, per EN/IEC 61009-2-1. That is the standard domestic and light-commercial fault level in many markets; if your panel's prospective short-circuit current exceeds 4.5 kA, you need to step up to a higher-rated device or add a current-limiting upstream MCB. Clip-on DIN rail mount, 36 mm wide (4 x 9 mm pitches). Terminals accept 1…16 mm² solid or 1…10 mm² flexible (with or without ferrule), with a 15 mm strip length and 2 N·m tightening torque. IP20 on the body, IP40 inside a modular enclosure. Pollution degree 3 — the unit handles conductive dust and condensation typical of industrial control rooms. Local signalling shows ON, OFF, and fault-trip status through the toggle — useful for a field tech walking a row of RCBOs to spot a tripped unit without touching anything. The toggle itself is the control type; no push-to-test button on this variant. The Acti9 range is Schneider's current-generation modular DIN-rail family, so this RCBO shares its platform with the rest of the iDPN Vigi sub-series. If you are standardising on Acti9 for a new panel build, the A9D44616 fits the same busbar system, same comb, same enclosure cut-outs as the rest of the range.","metaTitle":"Schneider Electric A9D44616 Acti9 iDPN Vigi, 16A C-curve, 30","metaDescription":"Schneider Electric A9D44616 Acti9 iDPN Vigi RCBO. 16A rated, C-curve, 30mA earth leakage, 4.5kA breaking capacity. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"4500 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPNa Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"4500 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$46.71","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ng/en/product/A9D44616/acti-9-idpna-vigi-rcbo-1p+n-16a-c-curve-4500a-300ma-type-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D44616/alternatives.json"},"ai":{"faq":[{"question":"What is the A9D44616's depth?","answer":"The depth is 73 mm. That dimension, combined with the 36 mm width and 85 mm height, determines the enclosure fill and whether it fits existing DIN-rail layouts."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D44616","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D44616 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}