{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D51232","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D51232","canonicalUrl":"https://aoctrl.com/schneider/A9D51232","factsUrl":"https://aoctrl.com/api/mcp/products/A9D51232","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, A9D51232, 2P, 32 A, C-curve, 10 kA breaking capacity, 300 mA earth leakage, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9D51232 is an Acti9 iC60 RCBO — a residual current breaker with overcurrent protection in a 2-pole, 36 mm wide package that clips onto a DIN rail. It combines a C-curve thermal-magnetic MCB for overcurrents with integrated earth-leakage protection at 300 mA sensitivity, all in one unit that saves a module of space compared to separate devices. Rated 32 A at 50 °C, with a breaking capacity of 10 000 A Icn at 240 V AC (IEC 61009-1), it handles the sort of lighting, socket-outlet, or small-load final circuits you see in commercial and residential distribution boards. In a panel where the prospective short-circuit current (PSCC) at the outgoer is under 10 kA, this device is a clean fit. If your supply transformer is close and the PSCC exceeds that, you'd need to step up to a higher-rated unit or add a current-limiting upstream breaker. The 300 mA earth-leakage sensitivity is a protection against fire risk from persistent arcing faults, not personnel shock protection (that's 30 mA and below). It's typical for circuits feeding equipment with natural leakage — heaters, computers, or fixed appliances — where a 30 mA RCD would nuisance-trip. For socket-outlet circuits where people touch the load, you'd want 30 mA; this 300 mA is for distribution or fixed-load outgoers. Depth of 75.5 mm and width of 36 mm (4 x 9 mm pitches) matter when you're laying out a high-density distribution board. That 75.5 mm is the dimension behind the panel face — the space the RCBO occupies inside the enclosure. If your gland plate or busbar shroud is tight, that's the number to check against your enclosure depth, not the 110 mm height. Terminals are screw-clamp: top accepts 1…25 mm² rigid or 1…16 mm² flexible; bottom accepts 1…16 mm² rigid or 1…10 mm² flexible. Wire stripping length is 13 mm for the bottom connection and 14 mm for the top — enough to get a good bite in the screw clamp without leaving bare copper exposed past the terminal.","metaTitle":"Schneider Electric A9D51232 Acti9 iC60 RCBO, 32 A, 10 kA, C-","metaDescription":"Schneider Electric A9D51232 Acti9 iC60 RCBO, 32 A rated current, 10 kA breaking capacity, 300 mA earth leakage, C-curve. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"110 mm","Standards":"IEC 61009-1 IEC 61009-2-2 AS/NZS 61009.1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Earthing system":"TN IT TT","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IEC 61009-1","Device short name":"iC60H2 RCBO","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom","[In] rated current":"32 A at 50 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"ON/OFF locking facilities","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9D51232/acti9-ic60h-rcbo-2p-32-a-c-curve-10-ka-300-ma-a-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D51232/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9D51232?","answer":"10 000 A Icn at 240 V AC, 50/60 Hz, conforming to IEC 61009-1."},{"question":"What earth-leakage sensitivity does this RCBO have?","answer":"300 mA — suitable for fire protection on circuits with natural leakage, not for personnel shock protection."},{"question":"What is the A9D51232's depth for panel fit?","answer":"75.5 mm behind the panel face, with a width of 36 mm (4 x 9 mm pitches)."},{"question":"Where can I buy the A9D51232 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D51232","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D51232 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}