{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D53613","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D53613","canonicalUrl":"https://aoctrl.com/schneider/A9D53613","factsUrl":"https://aoctrl.com/api/mcp/products/A9D53613","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 13 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, DIN rail mount.","salesMarkdown":"The Schneider Electric A9D53613 is an Acti9 iDPN Vigi residual-current circuit breaker with overcurrent protection (RCBO) — one compact unit that combines a 13 A thermal-magnetic MCB and a 30 mA earth-leakage module. It protects a single-phase final subcircuit (1 pole + neutral) against overload, short-circuit, and earth faults, all in a 36 mm wide (4 x 9 mm pitch) clip-on module that snaps onto a DIN rail inside a distribution board. Rated 13 A (In) with a C-curve magnetic trip (5 to 10 x In), so it's sized for general-purpose loads like lighting, socket outlets, and small appliances where inrush current is moderate — not for motor starting or transformer loads that need a D-curve. The 30 mA earth-leakage sensitivity (IΔn) meets the standard for personal protection in residential and commercial final circuits; it will trip on a fault current above 30 mA between live and earth. Breaking capacity is 6 kA Icn at 230…240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1 — that's the maximum fault current the device can safely interrupt. Clip-on mounting to DIN rail, 36 mm wide (4 x 9 mm pitches). Terminals accept 1…16 mm² rigid or 1…10 mm² flexible wire, with a stripping length of 15 mm and a tightening torque of 2 N·m. IP20 on the front, IP40 inside the modular enclosure.","metaTitle":"Schneider Electric A9D53613 Acti9 iDPN Vigi RCBO, 13 A, 30 m","metaDescription":"Schneider Electric A9D53613 Acti9 iDPN Vigi RCBO, 13 A rated, 30 mA earth leakage, C-curve, 6 kA breaking capacity. Active production, sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN N Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9D53613/residual-current-breaker-with-overcur-prot-rcbo-acti9-idpn-n-vigi-1p+n-13a-c-curve-6000a-asi-type-100ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D53613/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9D53613?","answer":"The A9D53613 has a breaking capacity of 6000 A Icn at 230...240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1."},{"question":"Where can I buy the A9D53613 and get a price?","answer":"The A9D53613 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for a firm quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D53613","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D53613 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}